A-3

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION

 

 

 

 

 

 

 

 

 

A-3

 

 

 

 

Duty Cycle-Applications

 

 

 

 

 

Volts at Rated Amperes

 

 

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40%

#TIG

 

 

31.0

 

 

 

 

 

 

 

 

 

 

 

 

 

275

 

 

 

 

 

 

 

 

AC/DC Stick / Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unbalance (70% Penetration ) AC TIG

 

 

20.2

 

 

 

 

 

 

 

 

 

 

 

 

 

255

 

 

 

 

 

 

 

 

 

60%

#TIG

 

 

29.0

 

 

 

 

 

 

 

 

 

 

 

 

 

225

 

 

 

 

 

 

 

 

AC/DC Stick / Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unbalance (70% Penetration ) AC TIG

 

 

18.0

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

100%

#TIG

 

 

28.0

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

AC/DC Stick / Balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unbalance (70% Penetration ) AC TIG

 

 

16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

 

Output Current

 

 

 

 

 

 

 

 

ADDITIONAL OUTPUT CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Open

 

 

Type of Output

 

 

 

 

 

 

 

 

 

 

 

Auxiliary Power

 

 

 

 

 

 

 

 

 

 

 

Range

 

 

 

 

Circuit Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K1825-1, K1826-1, K1826-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15Amp Circuit Breaker and NEMA 5-15R Duplex

 

 

 

 

 

 

 

2Amps DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receptacle for up to:

 

 

 

 

 

 

 

 

 

 

(STICK AND TIG)

 

CC (Constant Current)

 

 

115VAC 8Amp Auxiliary Power Receptacle

 

 

 

 

 

 

 

to

 

 

 

 

 

 

 

 

 

115VAC weld Switched Cooler Receptacle load

 

 

 

 

 

340Amps AC-DC*

 

AC/DC OCV: 75/68

 

AC/DC (GTAW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K1834-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stick (SMAW)

 

 

 

 

 

 

 

 

 

 

5 Amp Circuit Breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and grounded 220VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Euro(Schuko) receptacle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE

 

AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For all Stick, DC TIG, and Balanced AC TIG Welding

 

 

For Unbalanced AC TIG Welding Above 275 Amps:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at 275A/40% Duty Cycle with out Standard Power

 

 

255A/40% Duty Cycle, Auto-Balance Penetration with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factor Correction Capacitors

 

 

out Standard Power Factor Correction Capacitors

 

 

 

 

 

 

 

 

Based on the 1999 U.S. National Electrical Code

 

 

 

Based on the 1999 U.S. National Electrical Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

Type 75°C

 

Type 75°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

 

Type 75°C

 

 

 

 

 

 

 

Input

 

Fuse

 

 

 

 

 

 

 

 

 

 

Fuse

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ampere

 

 

Copper Wire in

Copper

 

 

 

 

 

 

 

 

 

Copper Wire in

 

 

Copper

 

 

 

 

 

 

Voltage /

 

(Super Lag)

 

Rating

 

 

Conduit AWG

Ground Wire in

 

 

(Super Lag)

 

 

 

Ampere

 

 

 

Conduit AWG

 

 

Ground Wire in

 

 

 

 

 

 

 

 

 

 

 

(IEC) Sizes

 

 

 

 

 

 

 

 

 

(IEC) Sizes

 

 

 

 

 

 

 

 

phase/

 

or Breaker

 

Rating on

 

40°C (104°F)

 

Conduit AWG

 

 

or Breaker

 

 

 

Rating

 

 

 

40°C (104°F)

 

 

Conduit AWG

 

 

 

 

 

Frequency

 

Size

 

 

 

 

Nameplate

 

 

Ambient

 

(IEC) Sizes

 

 

 

Size

 

 

 

 

 

 

 

 

 

Ambient

 

 

(IEC) Sizes

 

 

 

 

208/1/60

 

1

 

 

 

 

104

 

 

4 (21.2 mm2)

 

6 (13.3 mm2)

 

 

 

1

 

 

 

124

 

 

 

3 (26.7 mm2)

 

 

6 (13.3 mm2)

 

 

 

 

 

 

125

 

 

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

230/1/60

 

125

 

 

 

 

 

94

 

 

4 (21.2 mm2)

 

6 (13.3 mm2)

 

 

 

150

 

 

 

112

 

 

 

3 (26.7 mm2)

 

 

6 (13.3 mm2)

 

 

 

 

 

460/1/60

 

60

 

 

 

 

 

47

 

 

8 (8.4mm2)

 

10 (5.3mm2)

 

 

 

70

 

 

 

56

 

 

 

8 (8.4 mm2)

 

 

8 (8.4 mm2)

 

 

 

 

 

575/1/60

 

50

 

 

 

 

 

38

 

 

 

 

 

2)

 

2)

 

 

 

60

 

 

 

45

 

 

2)

 

 

2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 (5.3mm 2

 

10 (5.3mm 2

 

 

 

 

 

 

 

 

 

8 (8.4 mm 2

 

 

10 (5.3mm 2

 

 

 

 

220-230/1/50/60

 

125

 

 

 

 

 

95

 

 

4 (21.2 mm )

 

6 (13.3 mm )

 

 

 

150

 

 

 

109

 

 

 

4 (21.2 mm )

 

 

6 (13.3 mm )

 

 

 

 

 

380-400/1/50/60

 

80

 

 

 

 

 

55

 

 

8 (8.4mm2)

 

8 (8.4mm2)

 

 

 

90

 

 

 

63

 

 

 

6 (13.3 mm2)

 

 

8 (8.4 mm2)

 

 

 

 

 

415/1/50/60

 

80

 

 

 

 

 

50

 

 

8 (8.4mm2)

 

8 (8.4mm2)

 

 

 

90

 

 

 

58

 

 

 

6 (13.3 mm2)

 

 

8 (8.4 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K1826-1, -2

 

 

 

 

 

Height

 

 

 

 

 

 

Width

 

 

 

 

 

Depth

 

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K1827-1

 

 

 

 

 

31.0 in.

 

 

 

 

 

 

22.0 in.

 

 

 

 

 

26.0 in.

 

 

 

 

Approx. 397 lbs.

 

 

 

 

 

 

K2619-1,-2

 

 

 

 

 

787 mm

 

 

 

 

 

 

559 mm

 

 

 

 

 

660 mm

 

 

 

 

180 kgs.

 

 

 

 

 

 

K1825-1

 

 

 

 

 

49.7 in.

 

 

 

 

 

 

28.0 in.

 

 

 

 

 

41.0 in.

 

 

 

 

Approx.641 lbs.

 

 

 

 

 

 

 

 

 

 

 

1262 mm

 

 

 

 

711 mm

 

 

 

 

 

1041 mm

 

 

 

 

291 kgs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

 

RANGES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATING TEMPERATURE RANGE

 

 

 

 

 

 

 

STORAGE TEMPERATURE RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20°C to +40°C (-04° to +104°F)

 

 

 

 

 

 

 

 

 

-40°C to +85°C (-40° to +185°F)

 

 

TRANSFORMER INSULATION CLASS

180°C (H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 ALSO CALLED ʻINVERSE TIME" OR "THERMAL/MAGNETIC " CIRCUIT BREAKERS; CIRCUIT BREAKERS WHICH HAVE A DELAY IN TRIPPING ACTION THAT DECREASES AS

 

 

 

 

 

THE MAGNITUDE OF CURRENT INCREASES.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* 50/60HZ IEC Max. range exceeds 310A.

 

 

 

 

 

 

PRECISION TIG 275

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 9
Image 9
Lincoln Electric SVM162-B service manual Output Current, Maximum Open