TOC TOC
THEORY OF OPERATION | ||
| FIGURE E.3 – OUTPUT RECTIFICATION, CONTROL BOARD AND FEEDBACK |
|
Return to Section Return to Master
FROM
CONTROL
BOARD
OPTIONAL POWER
CORRECTIONFACTOR
CAPACITORS
POWER
BACKGROUND
CIRCUIT
63.5 VAC
REAR GANG | WORK |
|
POLARITY
SWITCH
BYPASS BOARD
FRONT ELECTRODE
HIGH FREQUENCY
SWITCH
PANEL
RECONNECT
X1
VAC78 X2
AC | DC | CHOKE |
| ||
| SCR |
|
BRIDGE |
| |
AC | DC | SHUNT |
TRANSFORMER
HIGH VOLTAGE TRANSFORMER
REAR ELECTRODE
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
|
|
|
|
|
|
|
|
|
|
|
| 115 VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GAS |
|
|
| VAC | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FAN |
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| THERMOSTAT |
|
|
| LEADSGATE FEEDBACK |
| SOLENOID | 115 |
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 115 VAC |
| VAC |
|
|
|
| VAC |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 115 |
|
|
|
|
|
|
|
|
|
|
| 115 |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
| 20 VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONTROL BOARD |
|
|
|
|
|
|
| THERMOSTAT |
|
| |||||||||||||||||||||
|
|
|
| 20 VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||
|
|
|
|
|
|
|
| ADVANCED CONTROL |
|
|
|
|
|
|
|
| LED's |
|
| ||||||||||||||||||||||||||||||
|
|
|
| MINIMUM |
|
|
|
|
|
|
|
|
|
|
|
| PANEL RECEPTACLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| OUTPUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| CONTROL |
|
|
|
|
| PROTECTION |
|
| METER |
| STICK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BOARD |
|
|
|
|
|
| TIG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SWITCH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BALANCE | POST | LOCAL/REMOTE |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| MAXIMUM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONTROL | FLOW |
| SWITCH |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT |
|
|
|
|
| REMOTE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| CONTROL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
OUTPUT RECTIFICATION, |
|
|
|
| RECEPTACLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
CONTROL BOARD AND FEEDBACK |
|
|
|
| The control board also monitors the thermostats and | ||||||||||||||||||||||||||||||||||||||||||||
The AC output from the main transformer secondary |
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||
is rectified and controlled through the SCR bridge. |
|
|
|
|
|
| controls the gas solenoid, the thermal light, the high | ||||||||||||||||||||||||||||||||||||||||||
Output current is sensed at the shunt as a low voltage |
|
|
|
| voltage transformer and the cooling fan. The optional | ||||||||||||||||||||||||||||||||||||||||||||
signal and fed back to the control board. The control |
|
|
|
|
|
| advanced control panel also plugs into and interfaces | ||||||||||||||||||||||||||||||||||||||||||
board senses the status and settings of the various |
|
|
|
|
|
| with the control board. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||
operator controls such as the Stick/TIG switch, the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
output controls, the remote control receptacle, the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
local/remote switch, the balance control and the post- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
flow control. Circuitry on the control board evaluates |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
these commands, compares them to the feedback |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
information received from the shunt and sends the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
appropriate gate firing signals to the output SCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
bridge. The control board regulates the firing of the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
output SCRs, which control the output of the machine. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
See SCR Operation. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|