TROUBLESHOOTING & REPAIR | ||||||
| TROUBLESHOOTING GUIDE |
| Observe Safety Guidelines |
| ||
|
|
| detailed in the beginning of this manual. | |||
| PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
|
| (SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
| FUNCTION PROBLEMS |
|
|
|
The AC wave balance control does | 1. The AC wave balance control is | 1. Check the AC balance control | ||||
not function properly. |
| operational only in the TIG mode. | (R2) and associated leads for | |||
|
|
|
| loose or faulty connections. See | ||
|
|
|
| the Wiring Diagram. |
|
|
NOTE: BEFORE REPLACING A |
| 2. The control board may be faulty. | ||||
| CONTROL BOARD |
|
|
|
|
|
If an Advanced Control Panel is |
|
|
|
| ||
installed, remove it and replace |
|
|
|
| ||
the Jumper in connector |
|
|
|
| ||
the machine functions normally, |
|
|
|
| ||
the Advanced Process panel or |
|
|
|
| ||
harness is defective. |
|
|
|
|
|
|
|
| ||
Gas | 1. If an advanced control board is | 1. Check plug J3 on the control | ||
too long. | installed, | check dip switch set- | board. Either the jumper plug or | |
| ting on | the board. | See | the advanced control board must |
| Installation Manual. |
| be plugged into J3. |