PRECISION TIG 275

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

F-16

TROUBLESHOOTING & REPAIR

F-16

 

TROUBLESHOOTING GUIDE

 

Observe Safety Guidelines

 

 

 

 

detailed in the beginning of this manual.

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

The AC wave balance control does

1. The AC wave balance control is

1. Check the AC balance control

not function properly.

 

operational only in the TIG mode.

(R2) and associated leads for

 

 

 

 

loose or faulty connections. See

 

 

 

 

the Wiring Diagram.

 

 

NOTE: BEFORE REPLACING A

 

2. The control board may be faulty.

 

CONTROL BOARD

 

 

 

 

 

If an Advanced Control Panel is

 

 

 

 

installed, remove it and replace

 

 

 

 

the Jumper in connector J-3. If

 

 

 

 

the machine functions normally,

 

 

 

 

the Advanced Process panel or

 

 

 

 

harness is defective.

 

 

 

 

 

 

 

 

Gas pre-flow and post-flow time is

1. If an advanced control board is

1. Check plug J3 on the control

too long.

installed,

check dip switch set-

board. Either the jumper plug or

 

ting on

the board.

See

the advanced control board must

 

Installation Manual.

 

be plugged into J3.

Return to Section TOC Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

Page 62
Image 62
Lincoln Electric SVM162-B service manual Installation Manual, Be plugged into J3