T1 MAIN TRANSFORMER TEST (continued)

 

 

 

 

Table F.3 - T1 Transformer Voltages

 

 

 

 

TEST POINTS

ACCEPTABLE VOLTAGES

 

 

 

 

SECONDARY WINDINGS

SECONDARY VOLTAGES

 

 

 

 

PLUG J11 PIN 8 (LEAD W209)

 

 

 

 

 

TO

20 VAC

 

 

 

 

PLUG J11 PIN 16 (LEAD R210)

 

 

 

 

PLUG J11 PIN 7 (LEAD #201)

18VAC

 

 

 

 

TO

 

 

 

 

PLUG J11 PIN 15 (LEAD #204)

78 VAC

 

 

 

 

X1 TO X2

 

 

 

 

PRIMARY WINDINGS

PRIMARY VOLTAGES

 

 

 

 

H1 TO H2

208 VAC

 

 

 

 

H1 TO H3

230 VAC

 

 

 

 

H1 TO H4

460 VAC

 

 

NOTE: If the input voltages vary, the secondary voltages will vary accordingly.

Based on 208/230/460 models. For other voltage models refer to appropriate Wiring Diagram.