Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

A-2

INSTALLATION

A-2

TECHNICAL SPECIFICATIONS-PRECISION TIG 275 (Domestic, Canadian & Export

 

K

RATED INPUT - SINGLE PHASE ONLY

Max. Amps With

Duty Cycle-Applications

Voltage + 10%

Max. Amps With Out

Number

40%

 

Power Factor Capacitor

Power Factor Capacitor

K1825-1

AC/DC Stick / Balance TIG

 

104/94/47

80/72/36

K1826-1

Unbalance (70% Penetration#) AC TIG

 

124/112/56

95/86/43

K2619-1

60%

 

86/78/39

64/58/29

 

AC/DC Stick / Balance TIG

208/230/460

 

Unbalance (70% Penetration#) AC TIG

95/86/43

62/56/28

R

100%

 

77/70/35

55/50/25

 

AC/DC Stick / Balance TIG

 

NRTL/C

Unbalance (70% Penetration#) AC TIG

 

73/66/33

40/36/18

 

Idle Amps

 

6/5/3

36/32/16

K1826-2

40%

 

47/38

35/28

AC/DC Stick / Balance TIG

 

K2619-2

Unbalance (70% Penetration#) AC TIG

 

56/45

43/34

 

60%

 

39/31

29/23

 

AC/DC Stick / Balance TIG

 

 

Unbalance (70% Penetration#) AC TIG

460/575

43/35

28/23

R

100%

35/28

25/20

 

AC/DC Stick / Balance TIG

 

 

Unbalance (70% Penetration#) AC TIG

 

33/26

18/14

NRTL/C

Idle Amps

 

3/2

16/13

 

Idle Power

 

300W

500W

 

40%

 

95/55/50

80/46/43

 

AC/DC Stick / Balance TIG

 

 

Unbalance (70% Penetration#) AC TIG

 

109/63/58

86/50/46

 

60%

 

80/46/42

64/37/34

K1827-1

AC/DC Stick / Balance TIG

220-230/

Unbalance (70% Penetration#) AC TIG

85/49/45

67/39/36

 

100%

380-400/415

70/41/37

52/30/28

N80

AC/DC Stick / Balance TIG

 

Unbalance (70% Penetration#) AC TIG

 

65/38/35

46/27/25

IEC 60974-1

Idle Amps

 

10/6/5

23/13/12

 

Idle Power

 

400W

500W

 

K1825-1,K1826-1 & K1826-2

.63 min.

.85 min.

RATED POWER FACTOR (STICK)K1827-1

 

.65 min.

.77 min.

 

RATED OUTPUT - NEMA EW1 Class ll (40) K1825-1,K1826-1,-2, K2619-1.-2

 

Duty Cycle-Applications

Volts at Rated Amperes

Amps

 

40%

31.0

 

275

AC/DC Stick / Balance #TIG

 

Unbalance (70% Penetration ) AC TIG

16.1

 

255

 

60%

29.0

 

225

AC/DC Stick / Balance #TIG

 

Unbalance (70% Penetration ) AC TIG

15.4

 

200

 

100%

28.0

 

200

AC/DC Stick / Balance #TIG

 

Unbalance (70% Penetration ) AC TIG

14.8

 

150

*Shown on Front of this IM manual with Under-Cooler Cart and Advanced Control Panel (Refer to Optional Equipment)

#Exceeds NEMA Unbalanced Load Specification comparable for Auto-Balance.

 

 

PRECISION TIG 275

Page 8
Image 8
Lincoln Electric SVM162-B service manual Installation, Unbalance 70% Penetration AC TIG 16.1 255 60% 29.0 225