PRECISION TIG 275

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

F-9

TROUBLESHOOTING & REPAIR

 

F-9

TROUBLESHOOTING GUIDE

 

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

OUTPUT PROBLEMS

 

 

 

 

The machine makes a very loud

1. Inspect the output terminal insu-

1.

Diode D1 may be shorted.

buzzing noise in DC Stick or in DC

lators for cracks or signs of over-

 

Check and replace if necessary.

TIG modes.

There is no current

heating.

2.

Check the polarity switch (S2) for

draw from the machineʼs output ter-

 

minals. (The machine is not exter-

 

 

proper function and correct con-

nally loaded).

 

 

3.

nections.

 

 

 

 

Perform the SCR Bridge Tests.

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.