TROUBLESHOOTING & REPAIR |
| |||||
TROUBLESHOOTING GUIDE |
|
|
| Observe Safety Guidelines | ||
|
| detailed in the beginning of this manual. | ||||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| |||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| |||
|
| OUTPUT PROBLEMS |
|
|
|
|
The machine makes a very loud | 1. Inspect the output terminal insu- | 1. | Diode D1 may be shorted. | |||
buzzing noise in DC Stick or in DC | lators for cracks or signs of over- |
| Check and replace if necessary. | |||
TIG modes. | There is no current | heating. | 2. | Check the polarity switch (S2) for | ||
draw from the machineʼs output ter- |
| |||||
minals. (The machine is not exter- |
|
| proper function and correct con- | |||
nally loaded). |
|
| 3. | nections. |
| |
|
|
| Perform the SCR Bridge Tests. |
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call