F-32

TROUBLESHOOTING & REPAIR

F-32

 

 

 

GAS (WATER) SOLENOID TEST (continued)

 

 

 

TEST PROCEDURE

 

 

 

7. Activate the torch trigger and check for

1.

Remove input power to the Precision TIG

 

 

 

275 machine.

 

 

 

approximately 115 VAC at the solenoid leads

2.

Remove the left case side.

 

 

 

(#231A and # 235). If the correct voltage is

 

 

 

present, the solenoid should activate and

3.

Perform the High Frequency Circuit

gas should flow.

 

 

4.

Disable Procedure.

 

 

 

8. If voltage is present at leads #231A and

Locate the gas solenoid in the torch connec-

#235 and the solenoid does not activate, the

 

 

 

tion box.

 

 

 

solenoid may be defective. The solenoid

5.

Put the mode switch S3 in the 2-Step TIG

can be further checked by removing leads

#231A and #235 from the solenoid and

 

 

 

position.

 

 

 

applying the external isolated 115 VAC sup-

 

 

 

 

 

 

 

ply to the solenoid terminals. If the solenoid

 

 

 

 

 

 

 

activates with the external supply but not

 

 

 

WARNING

 

 

when powered by the control board, the

 

 

 

 

 

 

 

problem may be in the control board. If you

 

 

 

ELECTRIC

SHOCK

CAN

 

 

 

hear solenoid activation but there is still no

 

 

 

KILL.

 

 

 

gas flow, check for restrictions in the line.

 

 

 

*With input power ON, there

9. When the test is complete, replace leads

 

 

 

are high voltages inside the

 

 

 

machine. Do not reach into

#231A and #235.

previously

 

 

 

the machine

or touch

any

10. Reassemble the two leads

 

 

 

internal part.

 

 

 

removed in the High Frequency Circuit

 

 

 

 

 

 

Disable Procedure.

 

 

 

 

 

 

 

 

 

11. Reassemble the left case side.

 

 

 

 

 

 

 

 

 

 

 

6.

Apply the correct input power to the TIG 275.

12. If a water solenoid is used, it can be tested

using the same procedures.

 

 

Return to Section TOC Return to Master TOC

PRECISION TIG 275

Page 78
Image 78