Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

F-53TROUBLESHOOTING & REPAIRF-53

SCR BRIDGE ASSEMBLY REMOVAL AND REPLACEMENT

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-888-935-3877.

DESCRIPTION

This procedure will aid the technician in the removal and replacement of the SCR bridge for maintenance or replacement.

MATERIALS NEEDED

3/8” Nut Driver

1/2” Nut Driver

7/16” Nut Driver

Pliers

Crimp Wire Cutters

Return to Section TOC Return to Master TOC

PRECISION TIG 275

Page 99
Image 99
Lincoln Electric SVM162-B service manual 53TROUBLESHOOTING & REPAIRF-53, SCR Bridge Assembly Removal and Replacement