| TROUBLESHOOTING & REPAIR | ||||||
|
|
| RETEST AFTER REPAIR |
|
|
|
|
| Should a machine under test be rejected for any reason requiring the removal of any | ||||||
| mechanical part that could effect the machineʼs electrical characteristics, or if any electrical | ||||||
| components are required or replaced, the machine must be retested. |
|
| ||||
| Input Volts/Hertz |
| INPUT IDLE AMPS |
|
|
|
|
|
|
|
|
|
| ||
|
| Maximum Idle Amps |
| Maximum Idle Amps |
| ||
|
|
|
| ||||
| 208/60 |
| (without PFC) |
|
| (without PFC) |
|
|
| 6 |
|
| 36 |
| |
| 230/60 |
| 5 |
|
| 32 |
|
| 460/60 |
| 3 |
|
| 16 |
|
| 575/60 |
| 2 |
|
| 13 |
|
|
|
| OPEN CIRCUIT VOLTAGES |
|
|
|
|
MAXIMUM AC OPEN CIRCUIT VOLTAGE
MAXIMUM DC OPEN CIRCUIT VOLTAGE
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE
AT MINIMUM OUTPUT SETTINGS
DC TIG Mode | 2 Amps @ 20 Volts |
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE
AT MAXIMUM OUTPUT SETTINGS
DC TIG Mode | 300 Amps @ 32 Volts |
RECOMMENDED METERS FOR MACHINE OUTPUT TESTS |
VOLTMETER: AC and DC True RMS Meter - Fluke 8922A or equivalent
AMMETER: Columbia Type AX AC or DC Tong Ammeter
IMPORTANT: IF OTHER TYPE METERS ARE USED, RESULTS MAY NOT BE ACCURATE.