F-42 TROUBLESHOOTING & REPAIRF-42
TYPICAL AC VOLTAGE WAVEFORM - MACHINE LOADED TO 2 AMPS
AC - TIG MODE
HIGH VOLTAGE/ HIGH FREQUENCY can damage test equipment.
Perform all voltage and waveform checks with high frequency circuit OFF.
Perform High Frequency Disable Procedure.
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
0V
20V | 5 ms |
AC BALANCE CONTROL IN “AUTO”
OUTPUT CONTROL AT MINIMUM.
This is the typical AC output voltage waveform generated from a properly operating machine. Note that each ver- tical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.
NOTE: Scope probes connected at
machine output terminals: (+) probe to electrode,
SCOPE SETTINGS | |
Volts/Div | 20V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |