Return to Section TOC Return to Master TOC

F-42TROUBLESHOOTING & REPAIRF-42

TYPICAL AC VOLTAGE WAVEFORM - MACHINE LOADED TO 2 AMPS

AC - TIG MODE

HIGH VOLTAGE/ HIGH FREQUENCY can damage test equipment.

Perform all voltage and waveform checks with high frequency circuit OFF.

Perform High Frequency Disable Procedure.

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

0V

20V

5 ms

AC BALANCE CONTROL IN “AUTO”

OUTPUT CONTROL AT MINIMUM.

This is the typical AC output voltage waveform generated from a properly operating machine. Note that each ver- tical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.

NOTE: Scope probes connected at

machine output terminals: (+) probe to electrode, (-) probe to work.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

PRECISION TIG 275

Page 88
Image 88
Lincoln Electric SVM162-B 42TROUBLESHOOTING & REPAIRF-42, Typical AC Voltage Waveform Machine Loaded to 2 Amps