Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

B-11

OPERATION

B-11

 

FIGURE B.4

 

START/CRATER CURRENT

4 Step Trigger Modes

UP-SLOPE

 

DOWN-SLOPE

Torch

Button

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

Pre-Flow

Post Flow

 

 

 

Pre-Flow

 

Post Flow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal Sequence

 

 

 

 

 

 

 

 

Hold the first trigger pull to maintain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the starting current and delay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

up-slope.

4 Step - Restart Enabled

(With DIP Switch #3 ON)

Torch

Button

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre-Flow

 

 

 

Post

Flow

 

 

 

 

Post

Flow

 

 

 

 

 

 

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hold the second trigger

 

Actuate the trigger

Actuate the trigger

Or actuate and hold the trigger,

 

 

 

 

 

 

 

pull for more than 1

 

holding it less than 1

again, during

during down-slope, to immediately

 

 

 

second to activate the

 

second, to begin

down-slope, to

end down-slope and maintain

 

 

 

restart function. When the

 

normal down-slope.

immediately end

crater current. Hold the trigger for

 

 

 

trigger is released

 

The following two

down-slope and stop.

more than 1 second to activate the

 

 

 

up-slope will occur.

 

options are available

 

 

 

 

 

 

 

 

 

 

restart function. When the trigger

 

 

 

 

 

 

 

 

 

during the normal

 

 

 

 

 

 

 

 

 

 

is released up-slope will occur.

 

 

 

 

 

 

 

 

 

down-slope period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Step - Restart Disabled

(With DIP Switch #3 OFF. As Shipped)

Torch

Button

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre-Flow

Post

Flow

 

 

 

 

Post

Flow

 

 

Post

Flow

Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hold the second trigger

 

 

Actuate the trigger

Actuate the trigger a third

Or actuate the trigger a third time,

 

 

 

pull for more than 1

 

 

holding it less than 1

time, during down-slope, to

during down-slope, to immediately

 

 

 

second to maintain

 

 

second, to begin

immediately end down-slope

end down-slope. Hold the third trigger

 

 

 

crater current before

 

 

normal down-slope.

and stop.

pull to maintain crater current.

 

 

 

stopping.

 

 

The following two

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

options are available

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

during the normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Step.eps

 

 

 

 

 

 

 

 

 

 

down-slope period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JRH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-17-07

PRECISION TIG 275

Page 27
Image 27
Lincoln Electric SVM162-B service manual Figure B.4