| TROUBLESHOOTING & REPAIR | ||||
| Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | |
| detailed in the beginning of this manual. |
|
| ||
| PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
| (SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
| FUNCTION PROBLEMS |
|
|
| The meter does not display V (volt) | 1. Toggle the display switch. It may | 1. Check the leads between the | ||
| or minimum current. |
| be dirty. | display switch and the control | |
|
|
|
| board. See the Wiring Diagram. | |
| NOTE: BEFORE REPLACING A |
| 2. The display switch may be faulty. | ||
|
| 3. The control board may be faulty. | |||
| CONTROL BOARD |
|
|
| |
| If an Advanced Control Panel is |
|
|
| |
| installed, remove it and replace |
|
|
| |
| the Jumper in connector |
|
|
| |
| the machine functions normally, |
|
|
| |
| the Advanced Process panel or |
|
|
| |
| harness is defective. |
|
|
|
|
The meter does not light up. Other 1. None | 1. Check the leads and connec- | |
machine functions are OK. | tions between the meter and the | |
| control board. See the Wiring | |
| Diagram. | |
NOTE: BEFORE REPLACING A | 2. The meter may be faulty. | |
3. The control board may be faulty. | ||
CONTROL BOARD | ||
If an Advanced Control Panel is |
| |
installed, remove it and replace |
| |
the Jumper in connector |
| |
the machine functions normally, |
| |
the Advanced Process panel or |
| |
harness is defective. |
|
Return to Section TOC Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call