PRECISION TIG 275

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

 

F-17

TROUBLESHOOTING & REPAIR

F-17

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

FUNCTION PROBLEMS

 

 

 

The meter does not display V (volt)

1. Toggle the display switch. It may

1. Check the leads between the

 

or minimum current.

 

be dirty.

display switch and the control

 

 

 

 

board. See the Wiring Diagram.

 

NOTE: BEFORE REPLACING A

 

2. The display switch may be faulty.

 

 

3. The control board may be faulty.

 

CONTROL BOARD

 

 

 

 

If an Advanced Control Panel is

 

 

 

 

installed, remove it and replace

 

 

 

 

the Jumper in connector J-3. If

 

 

 

 

the machine functions normally,

 

 

 

 

the Advanced Process panel or

 

 

 

 

harness is defective.

 

 

 

 

The meter does not light up. Other 1. None

1. Check the leads and connec-

machine functions are OK.

tions between the meter and the

 

control board. See the Wiring

 

Diagram.

NOTE: BEFORE REPLACING A

2. The meter may be faulty.

3. The control board may be faulty.

CONTROL BOARD

If an Advanced Control Panel is

 

installed, remove it and replace

 

the Jumper in connector J-3. If

 

the machine functions normally,

 

the Advanced Process panel or

 

harness is defective.

 

Return to Section TOC Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

Page 63
Image 63
Lincoln Electric SVM162-B service manual Display switch may be faulty