
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
TROUBLESHOOTING & REPAIR |
|
|
| |||||||||
TROUBLESHOOTING GUIDE |
|
|
|
|
|
| Observe Safety Guidelines | |||||
|
|
|
|
| detailed in the beginning of this manual. | |||||||
PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED |
|
|
| |||||
(SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
|
| ||||||
|
| TIG WELDING PROBLEMS |
|
|
|
|
|
|
| |||
No high frequency. The machine is | 1. If the machine is in a dirty envi- | 1. Check the high voltage trans- | ||||||||||
in the TIG mode and has normal | ronment with conductive contam- |
| former (T2). The normal resis- | |||||||||
output. |
| inants, check and clean the |
| tance of the secondary winding is | ||||||||
|
| spark gap with a low pressure air |
| 12.5k ohms. |
|
|
| |||||
|
| stream | per | the maintenance |
|
| WARNING | |||||
|
| 2. Check the spark gap operations |
|
| ||||||||
|
| instructions. |
|
|
|
|
|
|
|
|
| |
|
| and setting. Normal is (0.015”). |
|
|
|
|
| |||||
NOTE: BEFORE REPLACING A |
|
|
| ELECTRIC SHOCK | ||||||||
|
|
| ||||||||||
Refer | to | the | Maintenance |
|
|
| CAN KILL. | When | ||||
CONTROL BOARD |
| Section of this manual. |
|
|
| 115 VAC is applied | ||||||
If an Advanced Control Panel is | 3. Check | circuit | breaker CB1. |
|
|
| to T2, a very high | |||||
installed, remove it and replace |
|
|
| voltage | is | devel- | ||||||
|
|
| ||||||||||
the Jumper in connector | Reset if necessary. | oped on the secondary winding. For | ||||||||||
the machine functions normally, | 4. Check connection J12 on the | assistance, call the Lincoln Electric | ||||||||||
the Advanced Process panel or | control board. |
| Service Department. | |||||||||
harness is defective. |
|
|
|
|
| 3877. |
|
|
|
|
| |
|
|
|
|
|
| 2. Check R5, C6, C7, L2 and L3. | ||||||
|
|
|
|
|
|
| Replace if defective. |
|
|
| ||
|
|
|
|
|
| 3. The control board may be faulty. | ||||||
The High frequency is on continu- | 1. None |
|
|
| 1. Check plug J11 on the control | |||||||
ously in DC TIG or shuts off in AC |
|
|
|
|
| board. See the Wiring Diagram. | ||||||
TIG. |
|
|
|
|
| 2. Check | S2A for | |||||
|
|
|
|
|
|
| proper operation. See the Wiring | |||||
|
|
|
|
|
|
| Diagram. |
|
|
| ||
|
|
|
|
|
| 3. The control board may be faulty. |
Return to Section TOC Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call