28 Configuration management

Nortel Networks Confidential

 

 

The following table details the configurable properties of the System Output Manager tab:

Table 1 System Output Manager tab configurable properties

Configuration

 

 

Property

Format

Description

 

 

 

Send to File

Type: String

Name of file that

 

Range: Null, 1-500

additional detailed

 

logs should be sent

 

characters

 

to.

 

Default:

 

 

 

SystemOutLog

 

Number of Backup

Type: Integer

Number of logfiles

Logfiles

Range: N/A

that should be kept.

 

 

 

Default: 10

 

Maximum Size of a

Type: Integer (bytes)

Maximum size of the

Log File

Range:

log file in bytes.

 

When this size is

 

200000-2147483647

 

reached, the log file

 

 

 

Default: 200000

is rotated.

 

 

 

The following figures show the configurable properties of the RTP Media Portal tab:

Note: The configurable properties of the RTP Media Portal tab span more than one page and so, are shown in the next four figures.