36 Configuration management

Nortel Networks Confidential

 

 

Table 2 RTP Media Portal tab configurable properties

Chassis #

Type: String

 

Range: 0-255

 

Default: 1

Chassis identifier used to identify a specific CPX8216T chassis. This information is used by configuration scripts to synchronize RTP Media Portal configuration across multiple CX8216T chassis. Must be unique per chassis. Must match the Chassis # assigned to the blades during the staging of the portal.

Idle Session Audit

Type: String

Period

Range: 0-3600000

 

 

Default: 300000 (ms)

Long Idle Duration

Type: String

 

Range: 0-65535

 

Default: 24

Long Call Duration

Type: String

 

Range: 0-65535

 

Default: 576

The period of the audit that runs to detect idle media sessions on the Peripheral CPU (Blade).

This represents the maximum amount of time that a RTP Media Portal resource may remain validly idle. This has units of number of IdleSessionAuditPeriods.

This represents the maximum amount of time that an RTP Media Portal resource may remain active in a media session. This has units of number of Idle Session Audit Periods.

Public Network

Type: String

Detection Period

Range: 0-3600000

 

 

Default: 15000

The period of the audit that runs to detect the Public network interface on the Peripheral CPU (Blade). This has units of milliseconds. If the value is set to zero, then the audit is disabled.

PND Timeout

Type: String

 

Range: 0-10000

 

Default: 250

The amount of time that the Public Network Detection algorithm will wait for a response to a query sent to the default gateway. This has units of milliseconds. If the value is zero, no query will be made to the default gateway.

NN10035-111 Standard MCP 1.1 FP1 (02.02) April 2003

Copyright © 2003, Nortel Networks

Page 36
Image 36
Nortel Networks NN10035-111, MCP 1.1 FP1(02.02) manual RTP Media Portal tab configurable properties