34 Configuration management

Nortel Networks Confidential

 

 

Table 2 RTP Media Portal tab configurable properties

Discovery Probe

Type: String

Time Period

Range: 0-3600000

 

 

Default: 60000

Controls the frequency (in milliseconds) of registration messages (RSIPs) sent from the RTP Media Portal to the SIP Application Module in the absence of MGCP+ messaging from the SIP Application Module.

Host Receive Port

Type: String

 

Range: 1025-65535

 

Default: 3904

Port on which the RTP Media Portal listens for MGCP+ messaging from the SIP Application Module.

Note: The use of the default value for this property is highly recommended.

Polltimer Delay

Type: String

 

Range: 0-65535

 

Default: 20000

 

milliseconds

Polltimer Interval

Type: String

 

Range: 0-65535

 

Default: 65000

 

milliseconds

Time span (in milliseconds) required for startup and initialization of the cards. The host CPU waits this period of time before attempting to contact the cards. (This is how long the host waits to talk to the cards to ask if they are up yet.)

Note: The use of the default value for this property is highly recommended.

Interval (in milliseconds) at which the host polls the blades to ensure they are still available. (Intermediate checks just to make sure the blade is still up.)

Note: The use of the default value for this property is highly recommended.

Minor Port Usage

Type: Percent

Alarm Level

Range: 0-100

 

 

Default: 50

The percent usage at which the number of ports used on the public or private side of an RTP Media Portal (over all blades) causes a minor alarm.

NN10035-111 Standard MCP 1.1 FP1 (02.02) April 2003

Copyright © 2003, Nortel Networks

Page 34
Image 34
Nortel Networks NN10035-111, MCP 1.1 FP1(02.02) manual RTP Media Portal tab configurable properties