OK International DX-200/215 Troubleshooting, Problem, Possible Cause, Correction, Maintenance

Models: DX-200/215

1 20
Download 20 pages 16.69 Kb
Page 4
Image 4

8 TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTION

LCD does not

No power input

Check power cord

light

 

 

connections

 

 

 

Turn on power

 

 

 

 

 

System will not

Foot switch not

Check foot switch

actuate

 

plugged in or

 

connection

 

 

improperly

 

 

 

plugged in

Foot switch needs

 

Defective foot

 

to be repaired or

 

 

switch

replaced

 

Broken wire or

Unplug power cord

 

 

and disconnect air

 

 

loose connection

 

supply. Remove

 

 

inside unit

 

cover and check

 

 

 

 

for broken wires or

 

Defective

 

loose connections

 

solenoid

Replace solenoid

 

Defective PC

 

 

board

Replace PC board

 

 

 

 

 

System will not

Insufficient air

Increase air supply

pressurize

pressure

pressure

 

Air hoses not

Check connection

 

plugged in

Replace regulator

 

Regulator

 

 

 

 

defective

 

 

System will not

Vacuum setting is

Increase vacuum

pull vacuum

too low

setting

 

Defective

Replace solenoid

 

solenoid

valve

 

Defective

Replace venturi

 

vacuum venturi

Replace needle

 

Defective

 

valve

 

 

vacuum needle

 

 

 

 

valve

 

 

 

 

 

 

 

Inconsistent

Air bubbles in

Reduce vacuum

dispensing

Adhesives

setting

 

Dispense time is

Increase

 

too low

dispensing time

 

Dispense needle

Replace needle

 

 

started to clog

 

 

9MAINTENANCE

The dispenser is designed and built to be relatively maintenance free. To assure trouble free operation, the following recommendations should be followed:

1.Make certain air supply is clean and dry.

2.Avoid turning barrels upside down or laying barrel so that material may run through air line to internal components.

3.Avoid connecting the unit to excessive moisture or solvent saturation.

4.Avoid connecting air supply exceeding 100 psi (6.9 bars)

5.Use only Amyl Alcohol to clean outside surface of the main housing.

6.Use only soft cloth to clean the LCD.

10SPARE PARTS AND ACCESSORIES

For DX-3xx/2xx spare parts and accessories information, please visit the DX- 3xx/2xx User Guide webpage at http://www.okinternational.com

11LIMITED WARRANTY

OK International warrants this product to the original purchaser for a period of one

(1)year from date of purchase to be free from material and workmanship defects but not normal wear-and-tear, abuse and faulty installation. Defective product or subassembly and components under warranty will be repaired or replaced (at OK International's option) free of charge. Customer with defective product under warranty must contact the nearest OK International office or distributor to secure a return authorization prior to shipping the product to the assigned OK International authorized service center. For nearest OK International office or distributor contact information, please visit www.okinternational.com. OK International reserves the right to make engineering product changes without notice.

12I/O Configuration and End of Cycle Switch

For DX-3xx/2xx I/O Configuration and End of Cycle Switch information, please visit the DX-3xx/2xx User Guide webpage at http://www.okinternational.com

7

8

Page 4
Image 4
OK International DX-200/215 Troubleshooting, Problem, Possible Cause, Correction, Maintenance, Spare Parts And Accessories