Chapter 5: Alarm Programming
59
•To program a positive offset number (up to +10
degrees), enter the number on the keypad. The
OMA-P1104 recites the digits as they are pressed.
•To program a negative offset number (up to –10
degrees), first press PAUSE. The unit responds with a
“beep.” Next, enter the number on the keypad. The unit
recites the digits as they are pressed.
5. Press ENTER. The OMA-P1104 responds:“Enter.”
ENTER
TONE
PM
ENTER
TONE
PM
NOTE
If you find that your calibration offset exceeds
more than + 5 or – 5 degrees, other complicating
factors could be affecting normal operation of
the OMA-P1104. Call Omega for technical
assistance.
5.6.2 Interrogating Temperature Calibration
1. Press WHAT IS.
WHAT
IS
*
2. Press CALIBRATE.
6
CALIBRATE
3. Press the number key corresponding to the selected
temperature input.
1
CALL
DELAY
2
VOICE
REPS
3
INTERCALL
TIME
4
MAX CALLS
If a “beep” precedes the number as it is recited, then a
negative offset is indicated.
5.7 Obtaining Current TemperatureCurrent temperature readings for each temperature input may
be accessed at any time. The OMA-P1104 recites the input