Omegaphone® OMA-P1104 User’s Manual
80Communications / Dial-out:Problem1. The OMA-P1104 fails to dial out. a) The telephone number may be
incorrectly programmed.
b) Tone or pulse (the current dialing
method) is not compatible with the
telephone line on which the OMA-
P1104 is installed.
c) Recognition Time is too long. An alert
condition does not remain in effect long
enough to become a valid alarm.
Cause SolutionRecheck programming steps, Refer to
Chapter 4, Section 4.2.1.
Switch from the current setting: from tone to
pulse, or from pulse to tone. Refer to
Chapter 4, Section 4.3.
Reprogram Recognition Time. Set the
Recognition Time to the minimum duration
required to create a valid alarm. If possible,
test the new setting by deliberately creating
an alert condition. Refer to Chapter 5,
Section 5.3.
d) Max Calls is set to zero. Reprogram Max Calls. It is a good idea to
set your Max Calls to at least equal the
number of dial-out telephone numbers
programmed. Refer to Chapter 4,
Section 4.12.1.