Chapter 4: Communications Programming
37
OMA-P1104 announces Listen-in Time at the end of its first
round of status readings, saying, “Listen to the sound level for
(programmed time entered). The programmable range is from
0 to 255 seconds (or up to 4.17 minutes). The default value is
15 seconds.
NOTE
The microphone is also used to monitor high
sound level. See Chapter 5, Section 5.10 through
Section 5.11.1.
4.7.1 Programming the Listen-in Time
To program the Listen-in Time:
1. Press SET.
SET
#
2. Press LISTEN TIME. The OMA-P1104 will respond:
“Enter seconds.”
9
LISTEN TIME
SOUND
3. Using the number keys, enter the seconds. The OMA-
P1104 will recite the digits as they are pressed.
1
CALL
DELAY
2
VOICE
REPS
3
INTERCALL
TIME
4
MAX CALLS
5
TEMP LIMITS
6
CALIBRATE
7
RECOGNITION
TIME
8
CLOCK
9
LISTEN TIME
SOUND
0
ID NUMBER
POWER
4. Press ENTER. The OMA-P1104 will respond: “Enter.
ENTER
TONE
PM
ENTER
TONE