to always have DCD on. The modem is then plugged into a telephone line and it is ready to be called from a remote location.
In order to call the
When the computer calls the
APPENDIX 1 WMS-16
The
Instructions for setting up the
Wind Speed and Direction
Connect the wind sensor=s signal cable to the terminal strip on the back of the control module. This sensor has a four conductor shielded cable. The RED wire is connected to the +5 REF terminal; The BLACK wire is connected to a GROUND terminal; the GREEN wire (wind direction signal) is connected to the A7 terminal and the WHITE wire (wind speed signal) is connected to the P1 terminal. The
INITIALIZATION OF WIND SPEED AND DIRECTION SENSORS
Press EXC to get the MAIN MENU.
From the MAIN MENU press number 1. STATION SET UP.
From the Station Set Up menu press number 6. ADD OR REMOVE SENSORS. Then press Y, then ENTER. From the Sensor Types Menu select 2. WIND SPEED.
From the Wind Speed Sensors Menu select 1.
From the Sensor Input Channel select number 1, P1 (Pulse Counter). Then press ENTER. The Sensor configuration screen is displayed and it will show:
13