Omega Vehicle Security OM5-C manual Orderinginformation, Model, Maximum Input, Output

Models: OM5-C

1 56
Download 56 pages 46.38 Kb
Page 9
Image 9
MAXIMUM INPUT

SPECIFICATIONS Typical at TA = +25°C and +5V power.

Module

OM5-DT

Input Range

±1V to ±10V

Input Bias Current

±0.05nA

Input Resistance

2M(minimum)

Normal

Power Off

2M(minimum)

Overload

2M(minimum)

Input Protection

 

Continuous

240Vrms max

Transient

ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)

 

 

Excitation Voltage, VEXC

+10.0VDC ±2mV

Excitation current

40mA (maximum)

Excitation Load Regulation

±5ppm/mA

Excitation Stability

±15ppm/°C

Isolated Excitation Protection

 

Continuous

240Vrms max

Transient

ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)

 

 

CMV, Input to Output

 

Continuous

1500Vrms max

Transient

ANSI/IEEE C37.90.1-1989 (formerly IEEE-472)

CMR (50 or 60Hz)

100dB

NMR (–3dB at 1kHz)

120dB per decade above 1kHz

 

 

Accuracy(1)

±0.1% span, ±0.2mV RTI2

Nonlinearity

±0.02% span

 

 

Stability

±20V/°C

Input Offset

Output Offset

±40V/°C

Gain

±50ppm/°C

 

 

Noise

0.4Vrms

Input, 0.1 to 10Hz

Output, 100KHz

5mVpp

 

 

Bandwidth, –3dB

1kHz

Response Time (to 90% final value)

750s

 

 

Output Range

±5V

Output Resistance

50

Output Protection

Continuous short to ground

Output Selection Time

6.0s at Cload = 0 to 2000pF

(to ±1mV of VOUT)

±8mA

Output Current Limit

 

 

Output Enable Control

 

Max Logic “0”

+0.8V

Min Logic “1”

+2.4V

Max Logic “1”

+36V

Input Current, “0, 1”

0.5A

 

 

Power Supply Voltage

+5VDC ±5%

Power Supply Current

200mA @ Full Exc. load, 100mA @ No Exc. Load

Power Supply Sensitivity

±200V/% RTI(2)

Mechanical Dimensions

2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)

 

 

Environmental

–40°C to +85°C

Operating Temp. Range

Storage Temp. Range

–40°C to +85°C

Relative Humidity

0 to 95% noncondensing

Emissions

EN50081-1, ISM Group 1, Class A (Radiated, Conducted)

Immunity

EN50082-1, ISM Group 1, Class A (ESD, RF, EFT)

 

 

NOTES:

(1)Includes excitation error, nonlinearity, hysteresis and repeatability.

(2)RTI = Referenced to input.

27

ORDERINGINFORMATION

MODEL

MAXIMUM INPUT

OUTPUT

 

 

 

OM5-DT-1-C

±1V

±5V

OM5-DT-2-C

±2V

±5V

OM5-DT-3-C

±3V

±5V

OM5-DT-4-C

±4V

±5V

OM5-DT-5-C

±5V

±5V

OM5-DT-6-C

±6V

±5V

OM5-DT-7-C

±7V

±5V

OM5-DT-8-C

±8V

±5V

OM5-DT-9-C

±9V

±5V

OM5-DT-10-C

±10V

±5V

Page 9