Omega Vehicle Security OM5-C OM5-LTC Linearized Thermocouple Input Modules, Features, Description

Models: OM5-C

1 56
Download 56 pages 46.38 Kb
Page 12
Image 12
OM5-LTC

OM5-LTC

Linearized Thermocouple Input Modules

FEATURES

INTERFACES TO TYPES J, K, T, E, R, S, N, AND B THERMOCOUPLES

LINEARIZES THERMOCOUPLE SIGNAL

HIGH LEVEL VOLTAGE OUTPUTS

1500Vrms TRANSFORMER ISOLATION

ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION

INPUT PROTECTED TO 240VAC CONTINUOUS

160dB CMR

95dB NMR AT 60Hz, 90dB at 50Hz

±1V/°C DRIFT

CSA CERTIFIED, FM APPROVED, CE COMPLIANT

MIX AND MATCH OM5 TYPES ON BACKPANEL

DESCRIPTION

Each OM5-LTC thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, linearized and converted to a high level analog voltage output (Figure 1). This voltage output is logic-switch controlled, allowing these modules to share a common analog bus without the requirement of external multiplexers.

The OM5-LTC modules are designed with a completely isolated computer side circuit which can be floated to ±50V from Power Common, pin 16. This complete isolation means that no connection is required between I/O Common and Power Common for proper operation of the output switch. If desired, the output switch can be turned on continuously by simply connecting pin 22, the Read-Enable pin to I/O Common, pin 19.

The OM5-LTC can interface to eight industry standard thermocouple types: J, K, T, E, R, S, N, and B. Its corresponding output signal operates over a 0V to +5V range. Each module is cold-junction compensated to correct for parasitic thermocouples formed by the thermocouple wire and screw terminals on the mounting backpanel. Upscale open thermocouple detect is provided by an internal pull-up resistor. Downscale indication can be implemented by installing an external 47Mresistor, ±20% tolerance, between screw terminals 1 and 3 on the OM5-BP backpanels.

Signal filtering is accomplished with a six-pole filter which provides 95dB of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter are on the field side of the isolation barrier, and the other four are on the computer side.

After the initial field-side filtering, the input signal is chopped by a proprietary chopper circuit. Isolation is provided by transformer coupling, again using a proprietary technique to suppress transmission of common mode spikes or surges. The module is powered from +5VDC, ±5%.

A special input circuit provides protection against accidental connection of power-line voltages up to 240VAC.

+EXC

4

+In

Thermocouple

3

 

+2.5V

 

 

 

100M

 

 

 

 

 

Linearizer

4

 

 

 

NC

LPF

Isochopper™

LPF

6

Surge

Amplifier

Pat Pending

 

 

Suppression

 

 

 

and

 

 

20

VOUT

19

I/O Common

–In

2

 

–EXC

1

Backpanel Term Block

5

Protection

 

 

 

 

 

 

+V

–V

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Precision

 

 

Isolated

 

 

 

 

 

 

 

 

 

Computer-Side

 

 

 

 

 

 

 

 

Reference

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJC

1

2

22

17

RD EN\

Temp

Sensor

+V

Isolated

 

 

Power

–V

Field-Side

Oscillator

 

Power

 

 

+5V

16

Power Common

FIGURE 1. OM5-LTC Block Diagram.