Omega Vehicle Security OM5-C manual OM5-ITC Thermocouple Input Modules, Features, Description

Models: OM5-C

1 56
Download 56 pages 46.38 Kb
Page 49
Image 49
OM5-ITC

OM5-ITC

Thermocouple Input Modules

FEATURES

INTERFACES TO TYPES J, K, T, E, R, S, C, N AND B THERMOCOUPLES

HIGH LEVEL VOLTAGE OUTPUTS

1500Vrms TRANSFORMER ISOLATION

ANSI/IEEE C37.90.1-1989 TRANSIENT PROTECTION

INPUT PROTECTED TO 240VAC CONTINUOUS

160dB CMR

95dB NMR AT 60Hz, 90dB at 50Hz

±0.05% ACCURACY

±0.02% LINEARITY

±1V/°C DRIFT

CSA CERTIFIED, FM APPROVED, CE COMPLIANT

MIX AND MATCH OM5 TYPES ON BACKPANEL

DESCRIPTION

Each OM5-ITC Thermocouple input module provides a single channel of thermocouple input which is filtered, isolated, amplified, and converted to a high level analog voltage output (Figure 1). This voltage output is logic- switch controlled, allowing these modules to share a common analog bus without the requirement of external multiplexers.

The OM5-ITC modules are designed with a completely isolated computer side circuit which can be floated to ±50V from Power Common, pin 16. This complete isolation means that no connection is required between I/O Common and Power Common for proper operation of the output switch. If desired, the output switch can be turned on continuously by simply connecting pin 22, the Read-Enable pin to I/O Common, pin 19.

The OM5-ITC can interface to nine industry standard thermocouple types: J, K, T, E, R, S, C, N, and B. Its corresponding output signal operates over a 0V to +5V range. Each module is cold-junction compensated to correct for parasitic thermocouples formed by the thermocouple wire and screw terminals on the mounting backpanel. Upscale open thermocouple detect is provided by an internal pull-up resistor. Downscale indication can be implemented by installing an external 47Mresistor, ±20% tolerance, between screw terminals 1 and 3 on the OM5-BP backpanels.

Signal filtering is accomplished with a six-pole filter which provides 95dB of normal-mode-rejection at 60Hz and 90dB at 50Hz. Two poles of this filter are on the field side of the isolation barrier, and the other four are on the computer side.

After the initial field-side filtering, the input signal is chopped by a proprietary chopper circuit. Isolation is provided by transformer coupling, again using a proprietary technique to suppress transmission of common mode spikes or surges. The module is powered from +5VDC, ±5%.

A special input circuit provides protection against accidental connection of power-line voltages up to 240VAC.

FIGURE 1. OM5-ITC Block Diagram. +2.5V 100M

+EXC

4

+In

Thermocouple

3

–In

2

 

–EXC

1

4 NC

6

5

3

Surge

Suppression

and

Protection

LPF

Isochopper™

 

 

 

 

Amplifier

 

 

 

Pat Pending

 

 

 

 

 

+V

–V

 

Precision

 

Isolated

 

Computer-Side

 

Reference

 

 

Power

 

 

 

LPF

20

VOUT

19

I/O Common

22

RD EN\

Backpanel Term Block

Temp

Sensor

CJC

1

2

+V Manual background

–V Manual background

Isolated

Field-Side

Power

Power

Oscillator

17

+5V

16

Power Common

FIGURE 1. OM5-ITC Block Diagram.

16

Page 49
Image 49
Omega Vehicle Security OM5-C manual OM5-ITC Thermocouple Input Modules, Features, Description, OM5-ITCBlock Diagram