OmniTek 839-1290, 839-1320, 839-1340 owner manual F. Horizontal Termination, Step

Models: 839-1290 839-1320 839-1340

1 56
Download 56 pages 61.95 Kb
Page 12
Image 12
F. Horizontal Termination

F. Horizontal Termination

Type A - Up & Out Installations for Top Vent Configurations

Wall Thimble

90º Degree

Elbow

Pipe Length

Termination Cap

 

Wall Thimble Cover

Pipe Length

 

Type B - Rear Installations for Use with Rear Vent Kit

 

Snorkle Kit

 

Wall Thimble Cover

15-5/8 in.

 

 

 

 

(397mm)

 

 

C

21 in.

 

L

 

 

(533mm)

Pipe Length

Wall Thimble

 

Wall Strap

 

 

 

 

14 in. (356mm) Wide

(See Section 12 for conversion kit and venting components.) This is the only venting configuration that requires the use of the rear vent derating orifice that comes with the rear vent kit. NOTE: A Snorkel Kit is required.

Figure 5.3

Step 1.

Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.

Step 1. WARNING

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

Ensure vent components are locked together correctly.

Pipe may separate if not properly joined.

Step 2.

Direct vent pipe is designed with a locking connection. To connect the venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory. Wall thickness may vary. Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation needs.

Note: Female ends of direct vent pipe/elbows are designed to slide straight onto the male ends of adjacent pipes by orienting the pipe indentations so they match and slide into the entry slots on the male ends, see Figure 5.4. Push the pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs may not be visible from the outside. They may be located by examining the inside of the female ends.

Female Locking Lugs

Male Locking Lugs

Figure 5.4

Manual background WARNING

Fire Risk. Explosion Risk. Combustion Fume Risk.

Use vent run supports per installation instructions. Connect vent sections per installation instructions.

Maintain all clearances to combustibles.

Do NOT allow vent to sag below connection point to appliance.

Maintain specified slope (if required).

Improper support may allow vent to sag or separate.

12

Quadra-Fire • Topaz • 7009-113 Rev. J • 12/11

Page 12
Image 12
OmniTek 839-1290, 839-1320, 839-1340 owner manual F. Horizontal Termination, Step