OmniTek 839-1320, 839-1290, 839-1340 owner manual A. Maintenance Tasks, Inspect

Models: 839-1290 839-1320 839-1340

1 56
Download 56 pages 61.95 Kb
Page 43
Image 43
A. Maintenance Tasks

A. Maintenance Tasks

Inspect

 

Maintenance Tasks

Doors

1.

Inspect for scratches, dents or other damage and repair as necessary.

 

2.

Verify no obstructions to air flow.

 

3.

Verify maintenance of proper clearance to combustible household objects.

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

2.

Inspect glass for scratches and nicks that can lead to breakage when exposed to heat.

 

3.

Confirm there is no damage to glass or glass frame, Replace as necessary.

 

4.

Verify that latches engage properly and glass attachment components are intact and operat-

 

ing properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot

 

be removed.

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these

and Firebox Top

areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

3.

Verify unobstructed air circulation.

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as neces-

 

sary.

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as neces-

 

sary.

 

2.

Replace appliance if firebox has been perforated.

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if

 

necessary. USE CAUTION WHEN CLEANING/HANDLING CERAMIC BURNER.

 

3.

Replace ember material with new dime-size and shape pieces. Do not block ports or obstruct

 

lighting paths.

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

5.

Inspect for lifting and other flame problems.

 

6.

Inspect orifice for soot, dirt or corrosion.

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

9.

Inspect thermocouple/thermopile sensor rod for soot, corrosion and deterioration. Polish

 

with fine steel wool or replace as required.

 

10. Verify millivolt output. Replace as necessary.

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks,

 

fences or sheds) has been maintained.

 

4.

Inspect for corrosion or separation.

 

5.

Verify weather stripping, sealing and flashing remains intact.

Remote Controls

1.

Verify operation of remote.

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

Quadra-Fire • Topaz • 7009-113 Rev. J • 12/11