OmniTek 839-1290 Alcove Applications, = Vent Terminal, X = Air Supply Inlet, 1 cap, feet, caps

Models: 839-1290 839-1320 839-1340

1 56
Download 56 pages 61.95 Kb
Page 9
Image 9
= VENT TERMINAL

 

 

 

 

G

 

 

R

 

 

 

 

v

 

 

 

D

 

 

 

A

H

 

 

 

 

 

 

 

 

 

v

E

 

 

 

 

 

 

 

 

 

 

 

 

 

L

B

 

 

 

U.S.

 

 

 

 

 

 

 

v

 

B

 

 

 

v

B

(3 FT)

 

 

v

 

 

 

 

 

 

 

F

v

 

v

I

M

 

 

 

 

 

 

v

X

 

 

 

 

 

 

 

 

 

 

A

 

 

J or K

M

N

P

Q

(See Note 2)

V

T

V

S

Electrical

S

V

 

Service

 

 

 

 

 

 

 

 

 

 

D*

V

V

= VENT TERMINAL

X = AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

A

=

12 inches

clearances above grade, veran-

K

 

=

3 ft. (U.S.A.)

 

 

 

 

 

 

 

(See Note 1)

da, porch, deck or balcony

 

 

 

6 ft. (Canada)

clearance to a mechanical

 

B

=

12 inches

clearances to window or door

 

 

 

 

 

 

(powered) air supply inlet

 

L**

=

7 ft

clearance

above paved

 

 

 

 

that may be opened, or to per-

 

 

 

 

 

 

 

 

(See Note 1)

sidewalkor a paved driveway

 

 

 

 

manently closed window. (Glass)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

located on public property

 

D*

=

18 inches

vertical clearance to unventilat-

M*** =

18 inches

clearance

under veranda ,

 

 

 

 

ed soffit or to ventilated soffit lo-

 

 

 

 

 

 

porch, deck, balcony or over-

 

 

 

 

cated above the terminal

 

 

 

 

 

 

hang

 

 

 

 

 

*30 inches

for vinyl clad soffits and below

 

 

 

42 inches

vinyl

 

 

 

 

 

 

electrical service

S

=

 

6 inches

clearance from sides of

 

 

 

 

 

 

 

F

=

9 inches

clearance to outside corner

 

 

 

 

(See Note 3)

electrical service

 

G

=

6 inches

clearance to inside corner

T

=

 

12 inches

clearance above electrical

 

H

=

3 ft. (Canada)

not to be installed above a gas

 

 

 

 

(See Note 3)

service

 

 

 

 

 

 

meter/regulatorassembly within 3

 

Alcove Applications

 

 

 

 

 

 

feet (90cm) horizontally from the

 

N

 

=

6 inches ................. non-vinyl sidewalls

 

 

 

 

center-line of the regulator

 

 

 

 

 

 

 

 

 

 

12 inches ............... vinyl sidewalls

 

 

 

 

 

 

 

 

 

 

I

=

3 ft

clearance to gas service regula-

 

P

 

=

8 ft.

 

 

 

 

 

 

 

 

 

 

 

QMIN

 

RMAX

 

 

 

 

 

tor vent outlet

 

 

 

 

 

 

 

 

 

J

=

9 inches (U.S.A.)

 

 

1 cap

 

3 feet

 

2 x Q ACTUA L

 

 

 

 

 

 

 

 

 

 

 

12 inches (Canada)clearance to non-mechanical air

 

 

2 caps

 

6 feet

 

1 x Q ACTUA L

 

 

 

 

 

supply inlet to building or the

 

 

3 caps

 

9 feet

 

2/3 x Q ACTUA L

 

 

 

 

 

combustion air inlet to any other

 

 

 

 

 

 

 

 

 

 

 

4 caps

 

12 feet

 

1/2 x Q ACTUA L

 

 

 

 

 

appliance

 

 

 

 

 

 

 

 

 

 

 

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

NOTE: Local codes or regulations may require different clearances.

NOTE: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap is suggested. (See vents components pages.)

NOTE 2: Termination in an alcove space (spaces only open on one side and without an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be at least 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

NOTE 3: Location of the vent termination must not interfere with access to the electrical service.

Figure 4.4

WARNING: In the U.S.: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as slated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow side wall, overhang and ground clearances as stated in the instructions.

Quadra-Fire assumes no responsibility for the improper perfor- mance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PRO- TECTOR KIT BE INSTALLED.

Quadra-Fire • Topaz • 7009-113 Rev. J • 12/11

9

Page 9
Image 9
OmniTek 839-1290 Alcove Applications, = Vent Terminal, X = Air Supply Inlet, = Area Where Terminal Is Not Permitted, 1 cap