and Welcome to the Quadra-Fire Family!

and Welcome to the Quadra-Fire Family!

Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance.

This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation

of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each appliance is meticulously fabricated and gold and nickel surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: HANGING ON A CHAIN ON BACK OF APPLIANCE

 

 

Portland

 

 

 

 

 

 

 

 

SERIAL NO.

 

 

 

 

MODEL / MODÈLE: TOPAZ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1445 North HIghway

 

 

 

 

VENTED GAS FIREPLACE HEATER FOURNAISE AU GAZ AVEC

 

 

 

 

 

 

 

 

 

 

Colville, WA 99114

 

 

Report No. / Rapport Numéro

VENTILATION. NOT FOR USE WITH SOLID FUEL / NE PAS UTILISER

 

 

 

www.quadrafire.com

 

 

061-S-19B-5

 

 

AVEC LE COMBUSTIBLE SOLIDE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROVED FOR CANADA AND USA TO:

 

 

 

 

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS:

 

 

ANSI Z21.88a-2000 / CSA 2.33a-M-00 Vented Gas Fireplace Heaters, and

 

ANSI Z21.88a-2000 / CSA 2.33a-M-00 Fournaises au Gaz avec Ventilation,

 

 

applicable sections of UL307b Gas Burning Heating Appliances for

 

et les sections applicable de UL 307b Appareils de Chauffage Au Gaz pour

 

 

Manufactured Homes and Recreational Vehicles, CAN/CGA 2.17-M91

 

les Maisons Mobiles et les Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas

 

 

“Gas Fired Appliances for use at High Altitudes.” This appliance is

 

Fired Appliances for use at High Altitudes”.

 

 

manufactured for operation with Natural Gas.

 

 

 

Cet appareil est manufacturé pour l’opération avec le Gaz Naturel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE

 

Thermal Efficiency / Efficacité Thermique*

85% NG (blower on / avec ventilateur allumé)

 

 

 

Blower Electrical Rating / Évaluation du Ventilateur Électrique:

 

 

 

 

 

 

85% LP (blower on / avec ventilateur allumé)

 

 

 

 

 

 

* With Maximum horizontal length. / Avec longueur horizontale maximum.

 

 

 

115 V., 1.5 Amps, 60 Hz, 150 Watts

 

 

 

 

 

 

 

 

 

 

 

P.4.1-02 Canada Minimum pipe (P.4.1-02 Le canada tuyau minimum) 62.98% NG / 64.14% LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For use with Natural Gas

For use with Propane

 

 

 

 

 

 

Top Vent/Rear Vent:

 

Usage au Gaz Naturel

Usage au Gaz Propane

Bouche Supérieure/Conduit postérieur:

 

 

0-2000’

 

0-2000’

Input Rate on “HI” (BTU/Hr)

 

 

39,500

38,000

Puissance Évaluée à “HI” (BTU/Hr)

Input Rate on “LO” (BTU/Hr)

 

 

26,500

30,500

Puissance Évaluée à “LO” (BTU/Hr)

Maximum Output (BTU/Hr)**

 

 

33,600

32,500

Puissance Maximum (BTU/Hr)**

Main Burner Orifice (DMS)

 

 

.125”

 

.073” (49DMS)

Orifice du Brûleur Principal

Minimum Inlet Pressure (Inches W.C.)

4.5“

 

 

11“

Pression Minimum de la Valve (pouces W.C.)

Maximum Inlet Pressure (Inches W.C.)

7.0”

 

 

14”

 

ression Maximum de la Valve (pouces W.C.)

Manifold Pressure on “HI” (Inches W.C.)

3.5”

 

 

10”

 

ression du Collecteur d’ Échappement à “HI” (pouces W.C.)

**Max Venting, Blower On

 

 

 

 

 

 

 

** Ventilation Maximum, Ventilateur Allumé

This appliance equipped only for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for information on making these changes.

This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow National Fuel Gas Code ANSI Z223.1, or Canadian Installation Codes, CAN/CGA-B149 in Canada. Install and use only in accordance with manufacturer’s installation and operating instructions.NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.)

Cet appareil est équipé pour les altitudes de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les altitudes au dessus de 2000’ aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propriétaire pour les informations sur ces changements. Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez au National Fuel Gas Code ANSI Z223.1, ou aux code courant d'installation Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier. REMARQUE: Le conduit gaz doit être installé conformément aux codes de construction locaux. L'installation doit être effectuée par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la République de Massachusetts, l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.)

This appliance must be installed in accordance with the current Standard C N/CSA Z240 MH, Mobile Housing or with Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or when such standard is not applicable, NSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard.

WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer's instructions.

Installer l'appareil selon la norme CAN/C -Z240,

érie MM, Maisons mobiles ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces

normes ne sont pas pertinentes, utilisez la norme

N I/NC BCS 225.1/NFPA 501A, Manufactured Home Installations Standard.

AVERTISSEMENT: Ne pas utiliser l'appareil tant que toutes les sections n'ont pas ete assemblees et installees selon les instructions du fabricant.

This appliance must be properly connected to a venting system in accordance with the manufacturer's installation instructions.

Cet apprareil doit être correctement raccordé à un système d'évacuation, conformément aux instructions du fabricant

 

F

 

 

 

 

G

 

 

 

C

 

 

 

A

A

 

B

D

 

 

 

E

 

A

A

C

 

A.

Side of stove top to side wall

6.5" (152 mm)

 

 

Du coté du poêle au

coté

du mur

B.

Rear of stove top to back wall

6" (100 mm)

 

 

Le contrôle arrière au mur arrière

C.

Corner of stove top to side wall

1" (152 mm)

 

 

Du Coin du poêle du mur

D.

Minimum Alcove Height

54" (1372 mm)

Hauteur minimum du plancher au plafond

E.

Maximum Alcove Depth

36" (914 mm)

 

 

Profondeur maximale de l'alcôve

F.

Minimum Alcove Width

40"(915 mm)

 

 

Largeur minimum de l'alÔve

G. Mantle clearance from stove top

23"(584mm)

 

Espace libre du poêle au manteau

HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and strong enough to support the stove without a tipping hazard.

CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle sans le hasard de basculer.

Date of Manufacture / Date du Manufacturier

2008 2009 2010 Jan Feb Mar Apr May

Jun

Jul

Aug Sep Oct

Nov Dec

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE

Made in U.S.A. / Fait Aux États-Unis

250-7141

Serial Number

Barcode

Model Name

Test Lab & Report No.

SAMPLE OF SERIAL NUMBER / SAFETY LABELManufactured Date

2

Quadra-Fire • Topaz • 7009-113 Rev. J • 12/11

Page 2