To change the ingress rate of the Port 1, select option 1.

Change Fiber CIR (range 64 to 100000)> 142

To change the ingress rate of the Port 2, select option 6.

Change Port 2 CIR (range 64 to 100000)> 100000

To change the egress rate, select option 4 for Port 1 or option 9 for the Port 2. The egress rates are displayed. Select the desired egress rate.

PI

SA

Bandwidth Control - iConverter 2FXM2

iConverter, Serial Agent

Identifier -

 

 

 

 

 

 

 

Chassis Number

= 1

 

 

 

 

 

 

Slot Number

= 1

 

 

 

 

 

 

Model Number

= 8959N-0

 

 

 

 

 

 

 

 

1:

64 Kbps

11:

6 Mbps

Port 1

Control

 

2:

128 Kbps

12:

7 Mbps

--------------------------------------

 

3:

256 Kbps

13:

8 Mbps

1: Ingress CIR

 

100000 kbps

4:

512 Kbps

14:

9 Mbps

2: Ingress CBS

 

150 kB

5:

768 Kbps

15:

10 Mbps

3: Excess Traffic Policy

Drop

6:

1

Mbps

16:

20 Mbps

4: Egress rate

 

100 Mbps

7:

2

Mbps

17:

30 Mbps

5: Queueing

 

Fair Weight

8:

3

Mbps

18:

40 Mbps

 

 

 

9:

4

Mbps

19:

50 Mbps

Port 2

Control

 

10:

5

Mbps

20:

100 Mbps

--------------------------------------

 

 

 

 

 

6: Ingress CIR

 

100000 kbps

 

 

 

 

 

7: Ingress CBS

 

150 kB

 

 

 

 

 

8: Excess Traffic Policy

Drop

 

 

 

 

 

9: Egress rate

 

100 Mbps

 

 

 

 

 

10: Queueing

 

Fair Weight

 

 

 

 

 

Select Fiber Egress Rate from menu above (1-20) >

4.3.3Layer 2 Control Protocol Filter

Layer 2 Control Protocol Filter provides the ability to discard, forward or tunnel L2CP frames based on the network requirements. Select ‘discard’, ‘forward’ or ‘tunnel’..

The Layer 2 Control Protocol Filter is accessed by selecting option 9 from the Port configuration screen.

PI

SA

L2CP Control - iConverter 2FXM2

iConverter, Serial Agent

Identifier -

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8959N-0

1: Global L2CP Control

Forward

 

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

Select the appropriate option to configure the module for the desired operation.

Page 28

Page 28
Image 28
Omnitron Systems Technology 2FXM2 user manual To change the ingress rate of the Port 1, select option