Omnitron Systems Technology 2FXM2 user manual CNode Loopback

Models: 2FXM2

1 45
Download 45 pages 7.75 Kb
Page 41
Image 41

Once all the VLAN IDs have been assigned, select option 7 or 5 to save the entries.

PI

VLAN Membership - iConverter 2FXM2

 

iConverter, Serial Agent

Identifier -

 

 

 

 

 

 

 

Chassis Number = 1

Slot Number = 1

Model Number = 8959N-0

 

 

VLAN ID (VID)

Port 1

Port 2

BP A

BP B

Mngmnt

1:

100

 

Yes

No

No

No

No

Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

The VLAN membership entries are saved from the Port configuration screen, option 4.

4.3.10cNode Loopback

The 2FXM2 has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agent recognizes measurement packets and loops them back to the sending cNode device. Iometrix cNode equipment is required to obtain performance metrics.

cNode configuration is accessed by selecting option 10 from the Port configuration screen.

PI

SA

cNode Control -iConverter 2FXM2

iConverter, Serial Agent

Identifier -

 

 

Chassis Number = 1

Slot Number = 2

Model Number = 8959N-0

1:

cNode

Loopback

Disabled

2:

cNode

Rate Limit

64 Kbps

Enter Choice, Previous Screen(0), (H)elp, E(x)it >

From the menu, loopback can be enabled or disabled and the rate limit can be selected.