“Incomplete”, Discovery is in process, but is not yet completed.

Multiplexer State - Indicates the Multiplexer state (“Discard”, “Forward” or “Unknown”) of the remote ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs to the lower sublayer. If “Discard”, the remote partner is discarding non-OAMPDUs network frames. If “Unknown”, the Multiplexer state of the remote partner is indeterminate.

Parser Action - Indicates the Parser Action state (“Discard”, “Forward” or “Loopback”) of the remote ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs network frames to the higher sublayer. If “Loopback” is displayed, the remote partner is looping back non-OAMPDUs network frames. If “Discard” is displayed, the remote partner is discarding non-OAMPDUs network frames.

Critical Event - Indicates the Critical Event state (“Yes” or “No”) of the remote partner. If “Yes” is displayed, the local device has detected a Critical Event. If “No”, the local device has not detected a critical event.

Link Fault - Indicates the remote partner has detected a fault in the receive direction (“Yes” or “No”). If “Yes” is displayed, the receive link is down. If “No”, the receive link is up.

OAM Mode - Indicates the OAM mode (“Active” or “Passive”) of the remote partner.

Supports - Indicates the supported options (Variable Access “Var”, Link Event Notification “Events”, Loopback “LB” or blank if no options are supported) of the remote partner.

OUI - Indicates the three hex byte IEEE organizational specific identifier (or blank if unknown) of the remote partner.

802.3ah parameters can be accessed by selecting options 7 from the Port configuration screen. The fiber configuration screen is displayed.

PI

SA

802.3ah Control -iConverter GX/TM

iConverter, Serial Agent

Identifier -

 

 

 

 

Chassis Number = 1

Slot Number = 3

Model Number = 8923-1

Port = 1

1: 802.3ah OAM State

 

Disabled

Local Status

 

2: OAM Mode

 

Passive

Discovery State

Incomplete

3: Loopback Mode

 

Disabled

Multiplexer State

Disabled

4: Loopback Timeout

 

30 sec

Parser Action

Unknown

5: Unidirectional Mode

Not Available

 

 

 

 

Remote Status

 

 

 

 

Discovery State

Unknown

 

 

 

Critical Event

Unknown

 

 

 

Link Fault

Unknown

 

 

 

Multiplexer State

Unknown

 

 

 

Parser Action

Unknown

 

 

 

Mode

Unknown

 

 

 

Supports

Unknown

 

 

 

OUI:

00:00:00

Enter, Previous Screen (0), (n)ext page, (H)elp, E(x)it >

To configure the 802.3ah parameters for the UTP port, type an n and press <ENTER>.

Page 34

Page 34
Image 34
Omnitron Systems Technology GX/TM user manual Oui