3.2CONFIGURING DIP-SWITCHES

PI

SA

The GX/TM plug-in module has two board-mounted DIP-switches. The standalone unit has one bank of DIP-switches. The locations of the DIP-switches are illustrated below.

DIP-switch Locations

3.2.1Board-Mounted Bank 1 Settings

PI

SA

DIP-switch Bank 1 is available on both the plug-in and standalone modules. The table indicates the position of the switch; Left/Down or Right/Up. As indicated in the DIP-switch location diagram, Left and Right refers to the plug-in module and Down and Up refers to the standalone module.

PI

(Left/Right)

SA

(Up/Down)

Switch

Left/Down

Right/Up

(Factory Default)

 

 

SW1

AN:

Man:

Fiber Auto-Negotiation

Fiber Manual Negotiation

 

SW2

AN:

Man:

UTP Auto-Negotiate

UTP Manual

 

SW3

1000:

10-100:

UTP 1000Mbps

UTP 10-100Mbps

 

SW4

100:

10:

UTP 100Mbps

UTP 10Mbps

 

SW5

FDX:

HDX:

UTP Full-Duplex

UTP Half-Duplex

 

SW6 - SW8

See Link Mode DIP-Switch Table in Section 3.2.1.6

 

 

 

3.2.1.1SW1 - Fiber Auto/Manual Negotiation “AN Man”

When this DIP-switch is in the Left/Down fiber optic Auto-Negotiate “AN” position (factory default), the fiber optic port automatically determines the duplex and pause modes of the connecting fiber optic device. If the connecting fiber optic device cannot provide the proper signal to indicate its own mode of operation, the DIP-switch should be set to the Right/Up fiber optic Manual mode “Man” position.

Page 6

Page 6
Image 6
Omnitron Systems Technology GX/TM user manual Configuring DIP-SWITCHES