Omnitron Systems Technology GX/TM2 user manual Passwords

Models: GX/TM2

1 48
Download 48 pages 9.29 Kb
Page 11
Image 11

3.4CONFIGURING THE MODULE VIA COMMAND LINE INTERFACE

PI

SA

To configure, attach the GX/TM2 to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. The GX/TM2 Serial Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a serial cable to the serial port of the PC and the Serial Console Port of the GX/TM2. This is a standard asynchronous serial interface. The pin-outs are illustrated below.

Serial Connector Pin Outs

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the PC’s serial port to the following:

Bits Per Second:

57,600

Stop Bits:

1

Data Bits:

8

Parity:

NONE

Hardware Flow Control:

NONE

Power the chassis containing the GX/TM2 module and press <ENTER> to bring up a command line prompt on the attached PC.

The module is configured with the following defaults:

IP

 

IP Address:

192.168.1.220

IP Subnet Mask:

255.255.255.0

Passwords

 

Serial:

No password assigned

FTP:

No password assigned (not enabled)

Telnet:

public

SNMPv1/v2c Communities

READ:

public

 

 

WRITE:

public

 

 

SNMPv3 Parameters

 

 

 

User 1 name (read only):

guest

 

 

User 2 name (read/write):

admin

 

 

User 1 Privacy pwd:

publicguest

User 1 Authen pwd:

publicguest

User 2 Privacy pwd:

privateadmin

User 2 Authen pwd:

privateadmin