494
End code Contents
14 Format error
15 Entry number data error
18 Frame length error
19 Not executable
23 User memory protected
A3 Aborted due to FCS error in transmit data
A4 Aborted due to format error in transmit data
A5 Aborted due to entry number data error in transmit data
A8 Aborted due to frame length error in transmit data
10-3-34 I/O TABLE GENERATE –– MI

Corrects the registered I/O table to match the actual I/O table.

Command Format
@MI
x 100
x 101
Node no. Header
code TerminatorFCS
Response Format
@MI
x 100
x 101x 161x 160
Node no. Header
code End code TerminatorFCS
PC Settings
PC Mode UM Area
RUN MONITOR PROGRAM Write-protected Read-protected
--- --- OK --- OK
Execution Conditions
Commands Responses
Single Multiple Single Multiple
OK --- OK ---
End Codes An end code of 14 (format error) will be returned if the length of the command is
incorrect.
End code Contents
00 Normal completion
01 Not executable in RUN mode
02 Not executable in MONITOR mode
03 UM write-protected
13 FCS error
14 Format error
18 Frame length error
20 Couldnt create I/O table

Note The write-protected error code for this command is different from the other com-

mands.