DDAA1000/SRM User Guide

Changing System or Radio Configurations

To access the system or radio setups the user must remove all connectors from the DDAA1000/SRM or DD1000/SRM, then remove the cover and change the jumpers at location P1 and P2, and add a serial data cable (SRM6200E-SLC), supplied by Data-Linc Group, to connector P3. These jumper settings must be returned to the RUN/RF settings after reconfiguring the system or the radio or the units will not operate. See layout drawing.

There are 4 configurations of the jumpers.

1. RUN / RF

Normal DDAA/1000 and DD1000/SRM operations

2. CONFIG / RF

Serial port P3 to PC (computer) to access the radio parameters

3. CONFIG / PIC

To reprogram the system configuration setup memory

4. RUN / EXT

Factory use only - do not use

If changing the system configuration go to Appendix B.

If changing the radio parameters go to Appendix C.

Figure 9: Layout Drawing

12

DATA-LINC GROUP

PN 161-09981-002C

rev 8/04

Page 14
Image 14
Omron DDAA1000/SRM manual Changing System or Radio Configurations, Layout Drawing