Klinkmann Automation Omron Ethernet DAServer

23

This configuration view has 15 parameters (configuration requires proven network information, it can not be validated by the DAServer):

Enter Controller’s Network Address - to each network in the OMRON system can be assigned an unique network address between 0 and 127. When communicating with a node on another (remote) network, the entered value must be consistent with the network address (non-zero) assigned in the routing tables. The network address of 0 indicates the local network. Note: The default Network Address is 0.

Enter Controller’s Node Address - each OMRON Controller in Ethernet network must have its own unique node address between 1 and 126 (if Controller is inter- networked via other OMRON FA network then Node Address can have different range. For example, if inter-networked via SYSMAC LINK network, the Node Address range is between 1 and 62. Care should be taken to select a node address that will not conflict with other devices in the system.

Note: If destination node is OMRON PLC with Ethernet Unit installed then Controller Node Address must be configured according to following rules:

-if automatic conversion of Ethernet Unit’s IP address is used (also the node number setting rotary switch on the front panel of the Ethernet Unit is used) then Controller Node Address must be equal with the fourth byte (octet) of local IP address of Ethernet Unit;

-if automatic conversion of Ethernet Unit’s IP address is not used (IP Address Table is used) then Controller Node Address must be equal with the Node number configured in the Ethernet Unit’s IP Address Table.

Enter Controller’s IP Address. The Controller’s IP Address must match with IP address configured at corresponding controller Ethernet Unit system setup.

Enter Controller’s Port Number. Enter the UDP Port Number used for communications with this OMRON controller. The Port Number must much with the Port Number set in the OMRON controller by appropriate Ethernet Unit configuration software. Note: The default port number is 9600.

Enter Computer’s Network Address - the Local Network Address: the unique network address between 1 and 127 is assigned to each OMRON Ethernet network in the system. The entered value must be consistent with the network address assigned in the routing tables. When communicate only with nodes in the local network, you can set this Address to zero (default value).

Select the Controller Series. The available series are: CS1/CJ1, C200HX/HG/HE, CV-series, C/CPM2X and CQM1. To select Controller Series, click on the combo box button and make your choice from the list. Note: Only PLCs of CS1/CJ1, C200HX/HG/HE and CV series are directly accessible in Ethernet network. All other series PLCs must be inter-networked to get data from them.

Select Controller type. To select Controller type, click on the combo box button and make your choice from the list. The available types depends on selection in Controller Series combo box: CS1/CJ1 series offers 2 options (CS1 and CJ1), C200HX/HG/HE series offers one option (C200HX/HG/HE), CV-series offers 5 options (CV500, CVM1-CPU01-E, CV1000, CV2000 and CVM1-CPU11-E),

Omron Ethernet DAServer Ver 1.x User Manual Rev 1.4

17014m14

Page 25
Image 25
Omron DR 170 14 manual Klinkmann Automation Omron Ethernet DAServer

DR 170 14 specifications

The Omron DR 170 14 is a leading-edge digital infrared thermometer that has established a strong reputation for its accuracy and efficiency in measuring body temperature. This advanced device is particularly noted for its user-friendly design, making it suitable for both medical professionals and home use.

One of the key features of the Omron DR 170 14 is its non-contact measurement capability, allowing users to obtain temperature readings from a distance of about 1-3 centimeters. This feature is crucial in minimizing the risk of cross-contamination, especially in healthcare settings. The thermometer utilizes infrared technology to detect the infrared energy emitted by the body, ensuring quick and reliable readings in just seconds.

The Omron DR 170 14 also boasts a large, easy-to-read LCD display that provides clear visibility of temperature readings. This display is backlit, allowing for usage in low-light conditions, making it convenient during nighttime monitoring of children's temperatures.

Furthermore, the device includes a memory function that can store multiple temperature readings, assisting users in tracking fever patterns over time. This feature is invaluable for caregivers and healthcare providers as it allows for better assessment and decision-making regarding treatment plans.

In terms of accuracy, the Omron DR 170 14 is equipped with advanced measurement algorithms that enhance precision in readings, positioning it as a reliable option for temperature measurement. The thermometer can measure not only body temperature but also surface temperatures of objects and liquids, providing versatility beyond just clinical settings.

Another notable characteristic is its compact and lightweight design, which makes it highly portable and easy to carry around, whether in a medical bag or a home setting. The thermometer is also powered by batteries, ensuring that it remains operational even in case of power outages.

Overall, the Omron DR 170 14 stands out for its combination of modern technology, ease of use, and reliable performance. With its non-contact functionality, rapid readings, and memory features, it serves as an essential tool for anyone needing accurate temperature assessments, whether in a clinical or home environment. The thermometer exemplifies Omron's commitment to creating healthcare solutions that are not only innovative but also accessible to a wide range of users.