The following table lists the supported item names for the C-seriesPLCs:

Memory Area

Prefix

Tag

Type

Range

Value

Range

Format

Suffix

 

CIO area

IR

Discrete

IR0:00...IR511:15

0, 1

 

 

 

(Bit status)

 

 

or 0.00...511.15 (**)

 

 

 

 

CIO area

IR

Integer

IR0... IR511

(*)

u s b f g l

 

 

(Word contents)

 

 

or 0...511 (**)

 

m d e c

 

 

Latching Relay area

LR

Discrete

LR0:00... LR63:15

0, 1

 

 

 

(Bit status)

 

 

 

 

 

 

 

Latching Relay area

LR

Integer

LR0... LR63

(*)

u s b f g l

 

 

(Word contents)

 

 

 

 

m d e c

 

 

Holding Relay area

HR

Discrete

HR0:00... HR99:15

0, 1

 

 

 

(Bit status)

 

 

 

 

 

 

 

Holding Relay area

HR

Integer

HR0... HR99

(*)

u s b f g l

 

 

(Word contents)

 

 

 

 

m d e c

 

 

Auxiliary Relay area

AR

Discrete

AR0:00... AR27:15

0, 1

 

 

 

(Bit status)

 

 

 

 

 

 

 

Auxiliary Relay area

AR

Integer

AR0... AR27

(*)

u s b f g l

 

 

(Word contents)

 

 

 

 

m d e c

 

 

Completion flags for

TC

Discrete

TC0... TC511

0, 1

 

 

 

Timers/Counters(***)

 

 

 

 

 

 

 

Present Values for

PV

Integer

PV0... PV511

(*)

u s b f g l

 

 

Timers/Counters

 

 

 

 

m d e c

 

 

Data Memory area

DM

Discrete

DM0:0...DM9999:15

0, 1

 

 

 

(Bit status)

 

 

 

 

 

 

 

Data Memory area

DM

Integer

DM0...

(*)

u s b f g l

 

 

(Word contents)

 

 

DM9999

 

m d e c

 

 

 

 

 

 

 

 

 

Item/point names, corresponding to Input/Output register area CIO, may be without prefix.

(*)Value range for unsigned integer is from 0 to 65535 (item/point name with suffix "U" ("u") or without suffix), for signed integers from –32768 to 32767 (item/point name with suffix "S" ("s")) and for 16-bit BCD is from 0 to 9999. The value range for 32-bit integer is from -2147483648 to 2147483647 and for 32-bit BCD is from 0 to 99999999. Default value range for Integer Tag Type is unsigned integer.

(**)Represented memory area range is for C200HS type controller. For models C200H, C1000H and C2000H - accessible memory area ranges are 0:00...255:15 for Discrete items and 000...255 for Integer items.

(***) Read only

The following table lists the supported item names for the CPM2x PLCs: