Omron DR 170 14 manual Data, received Take into DASProtWarn

Models: DR 170 14

1 70
Download 70 pages 30.48 Kb
Page 61
Image 61

 

Klinkmann Automation Omron Ethernet DAServer

 

 

59

 

 

 

 

 

 

 

 

 

 

 

and writing

 

 

 

 

 

 

 

back modified

 

 

 

 

 

 

 

word value into

 

 

 

 

 

 

 

PLC’s memory.

 

 

 

 

 

 

 

Here the

 

 

 

 

 

 

 

processing of

 

 

 

 

 

 

 

first step failed.

 

 

 

 

 

 

<Socket_

Data, received

 

 

Take into

DASProtWarn

 

ControllerName>:

from PLC,

 

 

account,

 

 

 

Item <Pointer to

cannot be

 

 

when creating

 

 

 

Item_Class_Obj.>

converted into

 

 

client

 

 

 

(<ItemName>) read

right BCD

 

 

application.

 

 

 

illegal BCD value

value.

 

 

 

 

 

 

<WrongValue> hex,

Assigned value

 

 

 

 

 

 

returning 19999.

19999.

 

 

 

 

 

 

<Socket_

Data, received

 

 

Take into

DASProtWarn

 

ControllerName>:

from PLC,

 

 

account,

 

 

 

Item <Pointer to

cannot be

 

 

when creating

 

 

 

Item_Class_Obj.>

converted into

 

 

client

 

 

 

(<ItemName>) read

right BCD Long

 

 

application.

 

 

 

illegal BCD Long

value.

 

 

 

 

 

 

value <WrongValue>

Assigned value

 

 

 

 

 

 

hex, returning

199999999.

 

 

 

 

 

 

199999999.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Socket_

Data, received

 

 

Take into

DASProtWarn

 

ControllerName>:

from PLC,

 

 

account,

 

 

 

Item <Pointer to

cannot be

 

 

when creating

 

 

 

Item_Class_Obj.>

converted into

 

 

client

 

 

 

(<ItemName>) read

right BCD

 

 

application.

 

 

 

illegal BCD Floating

Floating Point

 

 

 

 

 

 

Point value

value.

 

 

 

 

 

 

<WrongValue> hex,

Assigned value

 

 

 

 

 

 

returning 0.0.

0.0.

 

 

 

 

 

 

 

 

 

 

 

 

 

<Socket_

Client

 

This error

Avoid writing

DASProtWarn

 

ControllerName>:

application tries

 

conditions could

values out-of-

 

 

 

Attempting write out-

to write the

 

happen writing new

range.

 

 

 

of-range value

value, invalid

 

value into specific

 

 

 

 

<WrongValue> into

for current Item

 

Item, for example,

 

 

 

 

Item <ItemName>

type.

 

BCD Item, when

 

 

 

 

(<Pointer to

 

 

invalid value “path

 

 

 

 

Item_Class_Obj.>),

 

 

through” standard

 

 

 

 

clamp to <Clamped

 

 

clamping methods .

 

 

 

 

Value>.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Please contact Klinkmann Support (support@klinkmann.com) if you face any other error messages with Log Flag “Error”.

Omron Ethernet DAServer Ver 1.x User Manual Rev 1.4

17014m14

Page 61
Image 61