Inputting Character Strings and Numbers

Section 1-11

 

 

 

 

 

Item

Function

 

Page

 

 

 

 

Extended

Enables usage of stand-alone operation. In stand-alone operation, screens can be changed

85

 

Functions

from PT touch switches/function keys or from Expansion I/O Units.

 

 

 

(EXTEND)

Sets data area allocations, comments, and other information for use with direct connection

19

 

 

 

 

operation. This function key appears only if direct connection has been turned ON in the Tool

 

 

 

Settings.

 

 

 

 

 

 

 

Set Environment

Accesses a modified version of the Tool Settings to enable changing certain Support Tool

16

 

(SET ENV)

operating parameters during operation.

 

 

 

Changing Menu Position and Grid Display

While creating data for the NT600M, there may be times when the screen data and the menu box overlap, making it difficult to see what you are doing. In such cases, you cam move or delete the menu box. The grid display can also be turned ON and OFF for either the NT600M or NT20M by pressing the Delete Key as long as grid display has been enabled in the tool settings (See page 15). The display position of the menu box and will change each time you press the Home Key as shown in the following tables.

NT600M with Grid Enabled

Delete Key

Initial

1

2

3

4

5

6

inputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu

Bottom

Top

None

Bottom

Top

None

Bottom

 

 

 

 

 

 

 

 

Grid

ON

ON

OFF

OFF

OFF

ON

ON

NT600M with Grid Disabled

Delete Key inputs

Initial

1

2

3

 

 

 

 

 

Menu

Bottom

Top

None

Bottom

 

 

 

 

 

Grid

OFF

OFF

OFF

OFF

NT20M

Delete Key inputs

Initial

1

2

 

 

 

 

Menu

Bottom

Bottom

Bottom

 

 

 

 

Grid

ON

OFF

ON

Note 1. The display position of the menu cannot be changed for the NT20M.

2.Screen data cannot be created and you cannot switch to the Screen Selection Display unless the menu is displayed.

1-11 Inputting Character Strings and Numbers

Inputting Character Strings You can use the Left, Right, Backspace, Delete, Insert, and Escape Keys when inputting character strings. Their functions are described below.

 

 

Moves the cursor to the left.

 

 

Moves the cursor to the right.

 

 

Deletes one character to the left of the cursor.

BS

 

 

Deletes one character at the cursor position.

DEL

 

 

 

Switches between insert mode and overwrite mode.

INS

 

 

 

Cancels character input string and returns to previous operation.

ESC

 

In insert mode, the cursor becomes a flashing rectangle and character strings are inserted at the cursor position. When text is inserted in this way, character strings to the right of the cursor position move to the right.

12

Page 17
Image 17
Omron NT-series, NT20M Inputting Character Strings and Numbers, NT600M with Grid Enabled, NT600M with Grid Disabled

NT600M, NT-series, NT20M specifications

Omron has established itself as a leader in the field of automation and control systems, with its NT series of human-machine interfaces (HMIs) being a prime example of their innovative technology. The NT20M and NT600M models stand out in this series, showcasing a blend of advanced features, robust design, and user-friendly interfaces that cater to various industrial applications.

The Omron NT20M is characterized by its compact size and versatility. Its 5.7-inch LCD display offers clear visibility, making it ideal for applications where space is a constraint. The graphical user interface allows operators to monitor and control processes easily. One of the standout features of the NT20M is its ability to support a wide array of communication protocols, facilitating integration with different types of PLCs and other devices. This flexibility ensures that the NT20M can be seamlessly incorporated into existing systems.

On the other hand, the Omron NT600M represents a more advanced option within the NT series. Featuring a larger 10.4-inch display, the NT600M enhances the user experience with its vibrant and responsive touchscreen interface. This model is designed for more complex applications, providing richer graphical capabilities, including animated graphics and customizable screens. The NT600M also supports more extensive data logging and can handle a greater quantity of data points, making it suitable for large systems that require detailed monitoring.

Both models leverage Omron’s proprietary technologies to enhance performance and reliability. The built-in alarm functions notify operators of any irregularities in the process, enabling quick response times to minimize downtime. Additionally, the NT series incorporates advanced security features, ensuring that sensitive information is protected from unauthorized access.

Interconnectivity is a critical aspect of modern industrial systems, and the NT20M and NT600M do not fall short in this regard. They are equipped with multiple communication ports, including Ethernet, RS-232, and USB, allowing for straightforward connectivity with a range of automation devices. This ensures that operators can access real-time data and analytics, leading to informed decision-making and streamlined operations.

In conclusion, the Omron NT20M and NT600M HMIs epitomize the convergence of form, function, and technology in industrial automation. With their unique features and robust capabilities, they empower operators to enhance productivity and efficiency within their operations, underscoring Omron's commitment to innovative solutions in the realm of automation.