Optima Company 1001 installation instructions P1 P2, Over ride, Reset Button

Models: 1001

1 32
Download 32 pages 832 b
Page 26
Image 26
Over ride

1001

Over ride

By pressing the over ride button (E) the timer programme is over ridden ie, if programme is in OFF time it will come ON and if in ON time will go OFF.

The timer will revert back to it set programme on reaching the next ON or OFF time.

When the programme is on over ride the sign x will be shown in the display window (B).

Reset Button

By the use of a pencil the reset button can be pushed (R). This will clear all programmes apart from those factory pre set.

Reset is only possible with switch (A) in set Clock position!

AIR PRESSURE SWITCH

2 fixing screw

 

Plate

White silicone

Reset Button P1

P2

Red silicone tube

Fig. 45

KROMSCHRODER

DL 1E

BROWN

 

 

 

3

1

2

2

 

 

3

1

BLACK

 

BLUE

 

 

 

 

2 fixing screw

KROMSCHRODER

 

 

HUBA 605

BLUE

 

 

 

 

 

 

3

1

2

 

 

 

BROWN

 

BLACK

 

 

HUBA 602

 

3

2

BLUE

 

1

 

 

 

 

BLACK

BROWN

1

3

2

32

1

HUBA 605

HUBA 602

Fig. 46