Optima Company 1001 installation instructions Technical data

Models: 1001

1 32
Download 32 pages 832 b
Page 4
Image 4
Technical data

1001

Technical data

Nominal Heat Input D.H.W. & C.H. (gross) Minimum Heat Input D.H.W. & C.H. (gross) Nominal Heat Input D.H.W. & C.H. (net)

Minimum Heat Input D.H.W. & C.H. (net) Nominal Heat Output D.H.W. & C.H. Minimum Heat Output D.H.W. & C.H.

Gas rate

Maximum burner pressure

Minimum burner pressure

Injector manifold Ø

Dimensions (o/all)

Height

Width

Depth

Weight (net)

Weight (gross)

Electricity supply:

Fuse rating: Mains

on P.C.B. in boiler

Electrical input

Domestic Hot Water flow:

(35°C rise)

Minimum Domestic Hot Water Flow Maximum domestic cold water Inlet pressure:

C.H. Safety valve pressure setting C.H. Expansion vessel capacity Min. heating circuit pressure Max. heating circuit pressure Low water pressure switch

Boiler water capacity:

Heating

Domestic hot water

Pipe connections:

Gas

Domestic cold water inlet

Domestic cold water outlet

Central heating flow

Central heating return

Pressure relief valve drain

Min. installation clearances. Sides: Left hand

Right hand Front

Min. height from worktop to base

NATURAL GAS (G20)

PROPANE LPG (G31)

34.8 kW

34.0 kW

15.1 kW

14.8 kW

31.3 kW

31.3 kW

13.6 kW

13.6 kW

27.9 kW

27.9 kW

11.8 kW

11.8 kW

3.3 m3S/h

2.39 kg/h

15 mbar

34.5 mbar

3.5 mbar

6.9 mbar

1.15 mm

0.72 mm

1020 mm

480mm

360mm

51kg

53kg

230V - 50 Hz

3 Amp. (main fuse)

F2 Amp (Fast)

160 Watt

11.4l/min. 2.5 l/min.

10,0 bar

3bar

7 litre

0,8 bar

3.0bar

0.4bar

1.5litre

0.5litre

22mm

15mm

15mm

22mm

22mm

15mm

5 mm

* Access to the front of the boiler must be

5 mm

available for maintenance (min. 600 mm)

50 mm*

(plus access for service)

200 mm

4