Optima Company Optima 3600O manual Troubleshooting, Symptom, Action, The main burner does not turn

Models: Optima 3600O

1 42
Download 42 pages 39.34 Kb
Page 32
Image 32
The main burner does not turn

Optima 3600

32

TROUBLESHOOTING

SYMPTOM

 

ACTION

 

The main burner does not turn

3. Check to make sure the thermostat is set high enough to turn on the

on with the pilot lit. (cont’d)

 

appliance.

 

4.

Check that the remote switch or the thermostat is turned on.

 

5.

Check for weak pilot flame. If flame is weak, check gas supply,

 

 

check pilot flame adjustment and check for blockage of pilot orifice.

 

6.

Check all connections to the valve for tight electrical contact.

 

7.

Check for 400-500 mV from the thermopile with the burner off and

 

 

200-250 mV with the burner on. If the voltages are lower, the

 

 

thermopile is defective.

 

8.

Check for defective gas valve.

 

 

 

 

The main burner shuts off

1.

This may be the normal operation of a wall thermostat installed to

when the appliance is warm.

 

appliances.

 

2.

Check for good pilot flames on the thermopile (see page 30).

 

3.

Check for good voltage from the thermopile.

 

4.

Check for proper functioning of venting system.

 

5.

Check wire connections. Expansion from heat affects a loose con-

 

 

nection

 

 

 

 

Sooty deposits on the glass

1.

If the flame is yellow and lazy, check for lint etc. around primary air

door.

 

shutter. Increase primary air by opening the primary air shutter if

 

 

necessary.

 

2.

Check for proper placement of the logs and branches. Ensure logs

 

 

and burner are clean. See that section in the instruction manual.

 

3.

Check for obstruction of the burner ports by the embers. See that

 

 

section in the instruction manual.

 

4.

Check for proper venting and blockage of the vent termination.

 

5.

Check manifold pressure and clock input rating for over-firing.

Sharp blue flames with flames

1. Too much primary air. Reduce primary air by closing the primary air

lifting off the burner at the

 

shutter. During cold temperatures, some flame lifting may occur

ends.

 

during start-up.

 

 

 

 

Convection blower does not

1.

The convection fan is thermostatically controlled. It will only turn on

turn on.

 

when the appliance is warmed-up. This may take up to 15 minutes

 

 

with the appliance on high.

 

2.

Check for 120VAC electrical supply to the appliance. (Is the cord

 

 

plugged in?)

 

3.

Check for proper mounting of the thermal snap disc.

 

4.

Check electrical connections.

 

5.

Check for defective thermal snap disc.

 

6.

Check for defective convection blower speed controller.

 

7.

Check for defective convection blower.

 

 

 

 