Optima Company Optima 3600O manual Optional Wall Switch Or Thermostat

Models: Optima 3600O

1 42
Download 42 pages 39.34 Kb
Page 18
Image 18
OPTIONAL WALL SWITCH OR THERMOSTAT

Optima 3600

18

OPTIONAL WALL SWITCH OR THERMOSTAT

If a wall mounted switch or a wall mounted thermostat is desired, Archgard recommends that the device be wired as shown in Fig 1. This will allow the original on/off rocker switch to be used incase the device that is mounted to the wall is inoperable.

Note: Archgard Industries does not manufacture, or sell any wall switch or wall thermostat, and will not extend warranty to them.

Thermostat / wall switch wire table Recommended Maximum Lead Length for two wires

Wire Size

Max. Length

 

 

14 GA.

50 Ft. (15.24 M)

 

 

16 GA.

32 Ft. (9.75 M)

 

 

18 GA.

20 Ft. (6.9 M)

 

 

20 GA.

12 Ft. (3.65 M)

 

 

22 GA.

9 Ft. (2.74 M)

 

 

VALVE CONNECTION for MILLIVOLT VALVE

ON / OFF SWITCH

OFF

PI

L

OT

O

N

HI

O

L

CAUTION: DO NOT CONNECT ANY AC VOLTAGE TO THE GAS VALVE.

Page 18
Image 18
Optima Company Optima 3600O manual Optional Wall Switch Or Thermostat, VALVE CONNECTION for MILLIVOLT VALVE