GENERAL INFORMATION

Optima 3600

6

GENERAL INFORMATION

APPLIANCE CERTIFICATION

This appliance is tested and certified to the following US and Canadian gas appliance standards.

-ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heaters,

-CAN/CGA-2.17-M91 Gas-Fired Appliance fo Use at High Altitudes

Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance.

INSTALLATION CODES

This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CSA-B149.1, in Canada. Electrical connections and grounding must be in accordance with local codes, if any, if not, follow the current CAN/CSA C22.1 in Canada and ANSI/NFPA 70 in the US. This appliance is certified for installation in a bedroom or a bedsitting room. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. This appliance must be installed in accordance with the current Standard CAN/CSA Z240 1411, Mobile Housing, or with the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard. Only for direct discharge without duct connection. This appliance must be direct vented using listed Simpson Dura-Vent components.

SPECIFICATIONS

 

Natural Gas (NG)

Propane (LP)

 

 

 

Manifold Pressure

1.7-3.5 in. W.C. (0.4-0.9 kpa)

6.5-10.0 in. W.C. (1.6-2.5kpa)

 

 

 

Min. Supply Pressure for

4.5 in. W.C. (1.1 kPa)

11.0 in. W.C. (2.7 kPa)

Purpose of Input Adjustment

 

 

Orifice Size

#43 DMS

#54 DMS

 

 

 

Nominal Input Rating

17,000 - 24,000 BTU/hr

19,000 -24,000 BTU/hr

 

(4.98 –7.03 kW)

(5.57 - 7.03 kW)

Altitude

0 - 4,500 ft. (0 - 1372 m)

0 - 4,500 ft. (0 - 1372 m)

 

 

 

Primary Air Opening

closed

25% open

 

 

 

HIGH ALTITUDE INSTALLATION

When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly de-rated and installed according to local codes, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CSA-B149.1, in Canada.