Optoma Technology EP705H specifications Lamp Changing Procedure

Models: EP705H

1 27
Download 27 pages 6.69 Kb
Page 25
Image 25

25

English

Changing the lamp

The projection display will detect the lamp life itself. It will show you a warning message “ Lamp is running out of standard lifetime. Be sure to replace the lamp as soon as possible.”. When you see this message, change the lamp as soon as possible.

Make sure the projection display has been cooled for at least 30 minutes before changing the lamp.

Warning: Lamp compartment is hot! Allow it to cool before changing lamps!

4Lamp Changing Procedure:

1.Turn off the power to the projector by pressing the Power/Standby button.

2.Allow the projector to cool down at least 30 minutes.

3.Turn off the main power switch.

4.Disconnect the power cord.

5.Use screwdriver to remove the screw from the cover. Œ

6.Remove the cover.

7.On the left side of the lamp module, push the electrical connector up to disengage it from the projector base. Ž

8.Remove the three screws from the lamp module.

9.Pull out the lamp module.

To replace the lamp module, reverse the previous steps.

Warning: To reduce the risk of personal injury, do not drop the lamp module or touch the lamp bulb. The bulb may shatter and cause injury if it is dropped.

Œ

Ž

Page 25
Image 25
Optoma Technology EP705H specifications Lamp Changing Procedure, To replace the lamp module, reverse the previous steps