Hoshizaki KM-61BAH III. Cleaning and Maintenance Instructions, A. Cleaning, Cleaning Procedure

Models: KM-151BAH KM-151BWH KM-61BAH KM-101BAH

1 22
Download 22 pages 62.9 Kb
Page 17
Image 17
III. Cleaning and Maintenance Instructions

III. Cleaning and Maintenance Instructions

IMPORTANT

Ensure all components, fasteners and screws are securely in place after any maintenance or cleaning is done to the equipment.

A. Cleaning

WARNING

1.Hoshizaki recommends cleaning this unit at least once a year. More frequent cleaning, however, may be required in some existing water conditions.

2.To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.

3.Always wear liquid-proof gloves to prevent the cleaning and sanitizing solutions from coming into contact with skin.

4.For safety and maximum effectiveness, use cleaning and sanitizing solutions immediately after dilution.

1.Cleaning Procedure

1)Dilute 5 fl. oz. (148 ml) of recommended cleaner Hoshizaki “Scale Away” or “LIME-A- WAY” (Economics Laboratory, Inc.) with 1 gallon (3.8 lit.) of water.

2)Remove the Air Filter. Remove all ice from the Evaporator and the Storage Bin.

Note: To remove cubes on the Evaporator, move the Control Switch on the Control Box to the “OFF” position and move it back to the “ICE” position after 3 minutes. The defrost cycle starts and the cubes will be removed from the Evaporator.

3)Move the Control Switch to the “OFF” position. Open the Door.

4)Disconnect the Silicone Hose to drain the water. See Fig. 6. Reconnect the Silicone Hose back in its correct position after all of the water has drained.

5)Pour the cleaning solution into the Water Tank. Move the Control Switch to the “WASH” position. Close the Door.

6)After 30 minutes, move the Control Switch to the “OFF” position.