Hoshizaki KM-101BAH, KM-61BAH, KM-151BWH F. Water Supply and Drain Connections - See Fig

Models: KM-151BAH KM-151BWH KM-61BAH KM-101BAH

1 22
Download 22 pages 62.9 Kb
Page 12
Image 12
Fig. 2

4)When installing the unit without legs, the perimeter where the machine touches the counter should be sealed with silicone to prevent water from leaking under the icemaker.

5)When installing the unit with legs on the bottom, use the four accessory legs adjustable from 6” (15.2 cm) to 7” (17.8 cm). Screw the legs tightly into the tapped holes in the base (see Fig. 3). Handle the icemaker carefully not to damage the exterior.

Tapped Hole

(Leg Mounting)

Base

Fig. 3 Adjustable Leg

Fig. 2

Fig. 3

F. Water Supply and Drain Connections - See Fig. 4

CAUTION

To prevent damage to equipment, do not operate this icemaker when the water supply is OFF, or if the pressure is below 10 PSIG (0.7 bar). Do not run the icemaker until proper water pressure is reached.

*Water supply inlet is 1/2” female pipe thread (FPT).

*A water supply line shut-off valve and drain valve should be installed. A minimum of 3/8” OD copper tubing is recommended for the water supply lines.

*Water supply pressure should be a minimum of 10 PSIG (0.7 bar) and a maximum of 113 PSIG (7.5 bar). If the pressure exceeds 113 PSIG (7.5 bar), the use of a pressure reducing valve is required.

*Drain outlet for icemaker dump is 3/4” FPT.

*Drain lines must have 1/4” fall per foot (2 cm per meter) on horizontal runs to get good flow. A vented tee connection is also required for proper flow.