*The icemaker requires no clearance at either side. But allow enough space at rear for water supply and drain connections, at least 12” (approx. 30 cm) clearance at front, and at least 0.6” (approx. 15 mm) clearance at top for maintenance.
D. Electrical Connection
WARNING
THIS APPLIANCE MUST BE GROUNDED.
This icemaker requires a ground that meets the national and local electrical code requirements. To prevent possible severe electrical shock injury to individuals or extensive damage to equipment, install a proper ground wire to this icemaker. Remove the plug from the electrical outlet before any maintenance, repairs or cleaning is undertaken.
CAUTION
The GREEN ground wire in the
*This icemaker must be plugged into an independent power receptacle which has enough capacity. The maximum allowable voltage variation should not exceed ± 10 percent of the nameplate rating. See the Nameplate.
*Usually an electrical permit and services of a licensed electrician are required.
E. Set Up
IMPORTANT
Do not place heavy objects exceeding 33 lbs (15 kg) on the Top Panel.
1)Unpack the icemaker, and remove all shipping cartons, tapes and packing BEFORE operating the unit.
2)Position the icemaker in a selected site. Clean the interior with soap and water and rinse thoroughly.
3)Level the icemaker in both the
8