Section 9: Trouble Shooting

Section 9: Trouble Shooting

Symptom

Possible Causes of Problems

Correction

 

 

 

 

One or more stations do

1.

Faulty Solenoid

Replace solenoid

not turn on

2. Wire broken or not connected

Repair wire and check connections

 

3.

Flow control stem screwed down, shutting valve off

Turn flow control stem counter-clockwise

 

 

 

until desired flow is achieved

 

4.

Programming is incorrect

Check to make sure the station in

 

 

 

question is set to water with a program

Stations turn on when

1.

Water pressure is too high

Install a pressure reducer

they are not supposed to

2. More than one start time is programmed

Reduce the number of start times for that

 

 

 

program

 

 

 

 

 

3.

Stations are set to water with both programs

Set station duration to 0 for suspect program

One station is stuck

1.

Faulty valve

Check that valve is not installed backwards

on and will not shut off

2.

Particles of dirt or debris stuck in valve

Remove dirt or debris from valve

 

3. Valve diaphragm faulty

Replace diaphragm

All stations do not turn on

1.

Transformer is defective or is not connected correctly

Check connections and outlet if NO A/C

 

 

 

power persists replace transformer

 

2. Programming is incorrect

Check Start Time and Watering Days

 

3.

Timer is in OFF mode

Turn dial to AUTO

Timer will not power up

1.

Transformer is defective or is not connected correctly

Check connections and outlet if NO A/C

 

 

 

power persists replace transformer

 

 

 

 

 

2.

Timer is not all the way down on the docking port

Push down timer on docking port until back

 

 

 

light turns on.

Stations continue to turn on and off

1.

More than one start time is programmed with overlapping schedules

Reduce the number of start times for that

when they are not programmed to

 

 

program

 

 

 

 

 

2.

Excessive pressure

Install pressure reducer

Persistant Fault

1. Short in wiring or solenoids

Check wiring or replace solenoid

18

07WTM002598 57926-24 rA.indd 18

2/16/07 2:07:26 PM

Page 19
Image 19
Orbit Manufacturing 91912, 91916, 57916, p 801 295 9820 Trouble Shooting, Symptom, Possible Causes of Problems, Correction