![Section 9: Trouble Shooting](/images/new-backgrounds/95089/9508937x1.webp)
Section 9: Trouble Shooting
Symptom | Possible Causes of Problems | Correction | |
|
|
|
|
One or more stations do | 1. | Faulty Solenoid | Replace solenoid |
not turn on | 2. Wire broken or not connected | Repair wire and check connections | |
| 3. | Flow control stem screwed down, shutting valve off | Turn flow control stem |
|
|
| until desired flow is achieved |
| 4. | Programming is incorrect | Check to make sure the station in |
|
|
| question is set to water with a program |
Stations turn on when | 1. | Water pressure is too high | Install a pressure reducer |
they are not supposed to | 2. More than one start time is programmed | Reduce the number of start times for that | |
|
|
| program |
|
|
|
|
| 3. | Stations are set to water with both programs | Set station duration to 0 for suspect program |
One station is stuck | 1. | Faulty valve | Check that valve is not installed backwards |
on and will not shut off | 2. | Particles of dirt or debris stuck in valve | Remove dirt or debris from valve |
| 3. Valve diaphragm faulty | Replace diaphragm | |
All stations do not turn on | 1. | Transformer is defective or is not connected correctly | Check connections and outlet if NO A/C |
|
|
| power persists replace transformer |
| 2. Programming is incorrect | Check Start Time and Watering Days | |
| 3. | Timer is in OFF mode | Turn dial to AUTO |
Timer will not power up | 1. | Transformer is defective or is not connected correctly | Check connections and outlet if NO A/C |
|
|
| power persists replace transformer |
|
|
|
|
| 2. | Timer is not all the way down on the docking port | Push down timer on docking port until back |
|
|
| light turns on. |
Stations continue to turn on and off | 1. | More than one start time is programmed with overlapping schedules | Reduce the number of start times for that |
when they are not programmed to |
|
| program |
|
|
|
|
| 2. | Excessive pressure | Install pressure reducer |
Persistant Fault | 1. Short in wiring or solenoids | Check wiring or replace solenoid |
18
07WTM002598 | 2/16/07 2:07:26 PM |