Error messages (continued)

If “T&S&M” is selected in the setup menu No. 008 (DISPLAY SEL), a message appears in the modedisplay whenever a warning or error occurs. When multiple events occur, the event with the highest priority is displayed.

Priority

Display

Description

 

 

 

 

High

Error messages

When an operational malfunction has occurred in the unit, the error number

 

 

(See error message table)

flashes and the error message is indicated on the counter display.

 

 

 

When SG has been selected as the input signal by the INPUT SELECT button, the

 

 

 

 

 

INT SG

INT SGdisplay will appear for the first two seconds at the start of operation (E-E

 

 

 

mode) when the REC button is pressed.

 

 

 

 

 

 

 

If there are no input signals--with the exception of the analog audio signals--

 

 

NO INPUT

supplied to the connectors selected by the INPUT SELECT button, the “NO

 

 

INPUT” display will appear for the first two seconds at the start of operation (E-E

 

 

 

 

 

 

mode) when the REC button is pressed.

 

 

Warning messages

When a warning occurs in this unit, the error number and warning message are

 

 

indicated on the counter display.

Low

(See error message table)

When multiple warnings occur, the warning with the highest priority is displayed.

 

 

 

 

UMID information display

This is displayed when UMID information is present on the input signal in E-E mode.

This lamp lights during tape playback when UMID information has been recorded on the tape. “NO-INFO” is displayed when there is no UMID information.

Display

 

Description

 

 

MATNO

Material number

 

 

COPY

Instance number (No. of copies)

 

 

OWNR

Country, organization, user

 

 

 

Reception status from GPS satellites when recording spatial coordinates (height above sea

 

level, longitude and latitude):

POS

HOLD : No reception from any satellite

2D

: Reception possible, but number of satellites is insufficient. Height above sea level

 

 

 

will not be accurate.

 

3D

: Good reception

DATE

Date

 

 

 

TIME

UTC (Coordinated Universal Time) and time difference with UTC

 

 

 

– 39 –